background image

10 

UKCA 524.10-2022.09

UKCA-Declaration of Conformity

Legislation - Designated Standards

•  Supply of Machinery (Safety) Regulations 2008 (MD)

EN 809:1998/AC:2010, EN ISO 12100:2010, EN 60335-1:2012/A13:2017 

•   The Restriction of the Use of Certain Hazardous 

Substance in Electrical and Electronic Equipment 

Regulations 2012   (RoHS)

•  Electromagnetic Compatibility Regulations 2016 

(EMC)

EN55014-1:2017/A11:2020, EN 55014-2:1997/A2:2008, 60034-1AC:2010, EN 61000-3-2:2014, 

EN 61000-3-3:2013

Name and address of the manufacturer: JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen - Germany - www.jung-pumpen.de

We hereby declare, under our sole responsibility, that the product is in accordance with the specified Legislation.

U 3 K  

(JP50031)

U 3 KS  

(JP50032)

U 3 KS  

(JP50033)

U 3 K SPEZ.  

(JP50043)

U 3 KS SPEZ.  

(JP50030)

U 3 KS SPEZ.  

(JP50042)

U 5 K  

(JP50672)

U 5 KS  

(JP50673)

U 5 KS  

(JP50674)

U 6 K E  

(JP50669)

U 6 K D  

(JP50670)

U 6 K ES  

(JP50671)

Authorized person for technical documention

JUNG PUMPEN - Stefan Sirges - Industriestr. 4-6 - 33804 Steinhagen

Steinhagen, 28-09-2022

______________________ 

i.V. ____________________

Stefan Sirges, General Manager 

Pascal Kölkebeck, Sales Manager

Other normative documents:

EN 60335-2-41:2003/A2:2010

VDE GS 40054271 (U3/3, UV3)

EN 62233:2008/AC:2008

EMC-VDE 40052857 (U3/3, UV3)

VDE GS 40020521 (U3/2, U5)

EMC-VDE 40020827 (U5)

VDE GS 40020499 (U6K D/3)

VDE GS 40020502 (U6K E/2)

EMC-VDE 92272 (U6 _E/D/1)

Содержание JP50030

Страница 1: ...U3 U3 K U3 K SPEZIAL U3 KS U3 KS SPEZIAL EN Instruction Manual JUNG PUMPEN DE B 55702 10 2022 09...

Страница 2: ...2 Installation example 40 x 40 mm 50 cm Installation example 50 x 50 mm 50 cm Installation GR 32...

Страница 3: ...avoid hazards Damage prevention in case of failure Like any other electrical device this product may fail due to a lack of mains voltage or a tech nical defect If damage including consequential damage...

Страница 4: ...stances must be decontaminated All safety and protection components must be re fitted and or made operational immediately after the works have been completed Their ef fectiveness must be checked befor...

Страница 5: ...njury The submersible pump is frost resistant down to 20 C when stored in dry conditions When installed however it must not be allowed to freeze in the water Transport The pump must always be lifted b...

Страница 6: ...be drained down to a re sidual water level of a few mm without using any special accessories To do so the foot strainer must be levered off with a screwdriver In the case of pumps with an attached co...

Страница 7: ...en and the air to escape from the pump housing it may be necessary to carry out a ventilation drilling Impeller blocked Solids and fibrous matter have become lod ged in the pump housing clean Decrease...

Страница 8: ...10m U3 K spezial 10m kg 3 5 4 4 3 8 DN 32 32 32 mm 10 10 10 S1 35 C S2 60 C 10 min 10 min 10 min S3 60 C 30 30 30 P1 W 320 320 320 P2 W 220 220 220 U V 1 N PE 230 1 N PE 230 1 N PE 230 f Hz 50 50 50 I...

Страница 9: ...9...

Страница 10: ...de We hereby declare under our sole responsibility that the product is in accordance with the specified Legislation U3 K JP50031 U3 KS JP50032 U3 KS JP50033 U3 K SPEZ JP50043 U3 KS SPEZ JP50030 U3 KS...

Страница 11: ...11...

Страница 12: ...pective owners 2022 Pentair Jung Pumpen Jung Pumpen GmbH Pentair Water Italy Srl Pentair Water Polska Sp z o o Industriestr 4 6 Via Masaccio 13 ul Plon w 21 33803 Steinhagen 56010 Lugnano Pisa 41 200...

Отзывы: