CLEANING

WARNING!

Before carrying out any works: disconnect the 
pump and the controls from the mains and take 
steps to ensure that no one else can reconnect 
them to the power supply.

WARNING!

Check the mains cable for signs of mechanical 
and chemical damage. Damaged or kinked ca-
bles must be replaced by the manufacturer.

NOTICE! 

If the water contains high levels of iron 

or lime, insufficient cleaning can result in irre

-

parable damage to the seal and thus also to the 
pump motor in the long term. Consequently, the 
pump must be cleaned at regular intervals ac-
cording to the hardness of the water.

Tightening torque M

A

for A2 screw materials 

for M 5       

M

A

 = 5 Nm

for Amtec 3  

M

A

 = 0,7 Nm

for Amtec 5  

M

A

 = 2 Nm

QUICK TIPS FOR REM-
EDYING FAULTS

Pump does not work

   

Check mains current (do not use a pin gauge)

   

Fuse faulty = may be too weak (please refer to 

Electrical Connection)

   

Mains supply cable damaged = repair to be 

carried out by manufacturer only

Pump runs but does not pump

   

Empty the pressure pipe or hose to allow the 

non-return valve to open and the air to escape 
from the pump housing, it may be necessary 
to carry out a ventilation drilling

Impeller blocked

   

Solids  and  fibrous  matter  have  become  lod

-

ged in the pump housing = clean

Decreased pumping performance

   

Foot strainer obstructed = clean

   

Pressure pipe obstructed = clean

   

Rotor worn out = repair to be carried out by 

the manufacturer 

      0197

JUNG PUMPEN GmbH - Industriestr. 4-6  

33803 Steinhagen, Germany

20

401.18-22.09

EN 12050-2:2001; 2015

Lifting plant for faecal-free wastewater DN 32

U 3 K  (JP50031)
U 3 KS  (JP50032)
U 3 KS  (JP50033)

U 3 K spez.  (JP50043)
U 3 KS spez.  (JP50030)
U 3 KS spez.  (JP50042)

Collecting and automatically lifting faecal-free 

waste water above the backflow level in buildings 

and sites

REACTION TO FIRE

NPD

WATERTIGHTNESS

Pass

EFFECTIVENESS (LIFTING EFFECT
- Pumping of solids

Pass

- Pipe connections

Pass

- Ventilation

NPD

- Minimum flow velocity

Pass

- Minimum free passage of the plant

Pass

- Minimum useful volume

NPD

MECHANICAL RESISTANCE
- Load bearing capacity and structural 
stability of collection tank for use

NPD

- Structural stability of collection tank 
for use inside buildings

NPD

NOISE LEVEL

70 dB(A)

DURABILITY
- of structural stability

NPD

- of lifting effectiveness

Pass

- of mechanical resistance

NPD

DANGEROUS SUBSTANCES

NPD

Содержание JP50030

Страница 1: ...U3 U3 K U3 K SPEZIAL U3 KS U3 KS SPEZIAL EN Instruction Manual JUNG PUMPEN DE B 55702 10 2022 09...

Страница 2: ...2 Installation example 40 x 40 mm 50 cm Installation example 50 x 50 mm 50 cm Installation GR 32...

Страница 3: ...avoid hazards Damage prevention in case of failure Like any other electrical device this product may fail due to a lack of mains voltage or a tech nical defect If damage including consequential damage...

Страница 4: ...stances must be decontaminated All safety and protection components must be re fitted and or made operational immediately after the works have been completed Their ef fectiveness must be checked befor...

Страница 5: ...njury The submersible pump is frost resistant down to 20 C when stored in dry conditions When installed however it must not be allowed to freeze in the water Transport The pump must always be lifted b...

Страница 6: ...be drained down to a re sidual water level of a few mm without using any special accessories To do so the foot strainer must be levered off with a screwdriver In the case of pumps with an attached co...

Страница 7: ...en and the air to escape from the pump housing it may be necessary to carry out a ventilation drilling Impeller blocked Solids and fibrous matter have become lod ged in the pump housing clean Decrease...

Страница 8: ...10m U3 K spezial 10m kg 3 5 4 4 3 8 DN 32 32 32 mm 10 10 10 S1 35 C S2 60 C 10 min 10 min 10 min S3 60 C 30 30 30 P1 W 320 320 320 P2 W 220 220 220 U V 1 N PE 230 1 N PE 230 1 N PE 230 f Hz 50 50 50 I...

Страница 9: ...9...

Страница 10: ...de We hereby declare under our sole responsibility that the product is in accordance with the specified Legislation U3 K JP50031 U3 KS JP50032 U3 KS JP50033 U3 K SPEZ JP50043 U3 KS SPEZ JP50030 U3 KS...

Страница 11: ...11...

Страница 12: ...pective owners 2022 Pentair Jung Pumpen Jung Pumpen GmbH Pentair Water Italy Srl Pentair Water Polska Sp z o o Industriestr 4 6 Via Masaccio 13 ul Plon w 21 33803 Steinhagen 56010 Lugnano Pisa 41 200...

Отзывы: