NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible 
party who maintains the system.

(*Hazardous Location

Motor End)

INSTALLATION AND SERVICE MANUAL

SUBMERSIBLE  

SOLIDS HANDLING 

PUMP

ENGLISH: PAGES 2-12

Installation and Service Manual 

For use with product built with Marathon® 
motor.

NOTE! To the installer: Please make sure you provide 
this manual to the owner of the equip ment or to the 
responsible party who maintains the system.

Item # E-03-554  |  Part # 5625-554-1  |  © 2018 Pentair plc  |  09/05/18 

Models   

S3R(X

*

)

*Used in Hazardous Locations Class I, 

Division 1, Groups C and D

HYDROMATIC

Содержание S3R

Страница 1: ...SUBMERSIBLE SOLIDSHANDLING PUMP ENGLISH PAGES 2 12 Installation and Service Manual For use with product built with Marathon motor NOTE To the installer Please make sure you provide this manual to the...

Страница 2: ...Pump is designed to be installed in a sump or wet location where drainage collects CALIFORNIA PROPOSITION 65 WARNING This product and related accessories contain chemicals known to the State of Calif...

Страница 3: ...also brings on the third pump in case of failure of either or both of the first two pumps Installing Sump Level Control Float Controls In either simplex duplex or triplex systems the lower or turn off...

Страница 4: ...e used but sew age may become septic and excessive solids may collect for the pump to handle A frequent pumping cycle is recommended for best op er a tion If an alarm system is used this con trol is u...

Страница 5: ...size the phase converter large enough for the amp draw specified on the motor nameplate not necessarily by motor horsepower The warranty on all three phase submersible motors is void if operated with...

Страница 6: ...n box When box is lifted off connection wires to motor will be exposed These wires may be burned but each wire is tagged with a metal marker giving wire number Cut the wires If the leads to the connec...

Страница 7: ...xpansion Use Permatex on plug threads Replacing Seals and Bearings 1 Drain all oil from motor chamber and seal chamber as described 2 Remove motor housing as de scribed 3 Remove bolts that hold seal c...

Страница 8: ...osed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps can operate in reverse di rec tion with out m...

Страница 9: ...9 Wiring Diagrams...

Страница 10: ...3 060000141 Seal Failure Wire Assy 1 14 079900002 Seal Housing 1 15 071450002 Bearing Housing 1 16 007400145 Rotor Shaft Assy 2 hp 230 1 60 1 077730135 Rotor Shaft Assy 2 hp 208 230 460 575 3 60 1 013...

Страница 11: ...3450 1 22 005170071 Capscrew SST 3 23 009750031 Retainer Ring 1 24 107430002 Bearing Housing 1 25 009200011 Upper Seal SC 1 26 005680071 Capscrew 4 27 005170081 Capscrew 4 28 24407C215 Stator 2 HP 230...

Страница 12: ...provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units that are not installed in accordance with...