background image

3

  

E-03-558 (07-05-20)

READ AND FOLLOW SAFETY INSTRUCTIONS!

 This is the safety alert symbol. When you see this symbol 

on your pump or in this manual, look for one of the following 
signal words and be alert to the potential for personal injury:

 warns about hazards that will cause serious 

personal injury, death or major property damage if ignored. 

 warns about hazards that can cause serious 

personal injury, death or major property damage if ignored.

 warns about hazards that will or can cause minor 

personal injury or property damage if ignored.

NOTICE:

 indicates special instructions which are important but 

not related to hazards.
•  Carefully read and follow all safety instructions in this manual 

and on pump.

•  Keep safety labels in good condition. 
•  Replace missing or damaged safety labels.
•  Make workshops childproof; use padlocks and master 

switches; remove keys.

 Read carefully the product installation & 

operation instructions. Failure to follow the instructions and 
warnings in the manual may result in serious or fatal injury 
and/or property damage, and will void the product warranty. 
This product must be installed by a qualified professional. 
Follow all applicable local and state codes and regulations. In 
the absence of such codes, follow the current editions of the 
National Plumbing Code and National Electrical Code (NEC), as 
applicable.

 This product is used in conjunction with a 

system containing a tank under pressure, which may over time 
corrode, weaken and burst or explode, causing serious or fatal 
personal injury, leaking or flooding and/or property damage. 
To minimize risk, a licensed professional must install and 
periodically inspect and service the product and system. A drip 
pan connected to an adequate drain must be installed if leaking 
or flooding may cause  property damage. Do not locate system 
in an area where leaking may cause property damage.

 This control is capable of running pumps 

to pressures that may exceed the limitations of system 
components. Never set the operating pressure higher than that 
of the safe system capacity.

 This control can be adjusted to a narrow 

pressure differential. An improperly sized tank can cause the 
pump to cycle and lead to pump damage. This may require a 
larger pressure tank than is normally used.

CALIFORNIA PROPOSITION 65 WARNING

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, 
birth defects or other reproductive harm.

ELECTRICAL SAFETY

 

ELECTROCUTION HAZARD: 

Must be installed by 

a qualified professional. First disconnect all electrical power 
before attempting service. For your safety, the installation and 
operation instructions must be followed to minimize the risk of 
electric shock, property damage or personal injury.

GENERAL SAFETY

 Do not touch an operating motor. Modern 

motors can operate at high temperatures. To avoid burns when 
servicing pump, allow it to cool for 20 minutes after shutdown 
before handling.
•  Do not allow pump or any system component to freeze. To do 

so will void the warranty. See “Warranty” on Page 10.

•  Pump only water with this pump.
•  Periodically inspect pump and system components.
•  Wear safety glasses at all times when working on pumps.
•  Keep work area clean, uncluttered and properly lighted. 

Store all unused tools and equipment.

•  Keep visitors at a safe distance from the work areas.

 Pump body may explode if used as a booster 

pump unless a relief valve capable of passing full pump flow at 
75 psi is installed.

 A water test must be taken before installation 

of any water treatment equipment. The water quality can 
significantly influence the life of your system. You should 
test for corrosive elements, acidity, total solids and other 
relevant contaminants, including chlorine and treat your water 
appropriately to ensure satisfactory performance and prevent 
premature failure.

 Use only lead-free solder and flux for all  

sweat-solder connections, as required by state and federal 
codes.
 

 

EXPLOSION OR RUPTURE HAZARD: 

A relief 

valve must be installed to prevent pressure in excess of local 
code requirement or maximum working pressure designated in 
the product manual, whichever is less. Do not expose system 
to freezing temperatures or temperatures in excess of 120°F 
(49°C). Failure to properly size the system or follow instructions 
in the manual may result in excessive strain on the system and 
may lead to product failure, leakage, flooding and/or property 
damage.

SAFETY INFORMATION

Содержание C4H(X)P

Страница 1: ...t 056255581 2020 All Rights Reserved INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLE SOLIDSHANDLING PUMP C4H X P H4Q X P S4K X P S4L X P S4LV X P S4B X P S6L X P S6A X P S8F X P Used in hazardous locations Class I Division I Groups C D FM ...

Страница 2: ...TABLEOFCONTENTS SECTION PAGE Safety Information 3 General Information 4 Pump Installation 5 Pump Operation Maintenance 6 Troubleshooting 7 Parts List 8 Wiring Diagrams 15 Warranty 16 ...

Страница 3: ...ial An improperly sized tank can cause the pump to cycle and lead to pump damage This may require a larger pressure tank than is normally used CALIFORNIA PROPOSITION 65 WARNING This product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm ELECTRICAL SAFETY ELECTROCUTION HAZARD Must be installed by a qualified profes...

Страница 4: ...inding temperature the starter in the panel breaks power to the pump Once the sensor resets the starter is automatically reset for FM for continued operation of the pump This circuitry is supplied in a Hydromatic control panel The sensors are set to trip at 130 C Failure to install such circuitry would negate FM approvals and all warranties by Hydromatic POWER CORDS The power cord and heat sensor ...

Страница 5: ...nge Pumps shipped from the factory as 460 volt 3 phase cannot be rewired to any other voltage TO RE WIRE THE PUMP FROM 230V TO 460V 3 PHASE Only a 230V pump from the factory is considered dual voltage a cord label clearly states the factory wound voltage 1 Remove all six 7 cap screws then raise the cord cap assembly enough to slip a prying instrument on opposite sides between the cord cap casting ...

Страница 6: ...ble motors that are out of warranty can be serviced in the field by any reliable motor service shop Any pump that is in warranty must be returned to the factory for service or repaired at an authorized Pentair Hydromatic service center Charges will not be allowed if in warranty pump is not taken to an authorized Pentair Hydromatic service center When field service is performed on a pump these inst...

Страница 7: ...city 1 Discharge gate valve may be partially closed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps can operate in reverse direction without much noise or vibration 4 Discharge head may be too high Check total head with gauge when pump is operating Total head is discharge gauge pressure converted ...

Страница 8: ...5 CORD CAP ASSEMBLY 4 4 W 1 25 107550312 SEAL PLATE 1 132531001 OIL DIELECTRIC VARIES PUMP PARTS LIST 1 2 3 4 5 7 8 12 11 15 16 18 19 10 A1 A2 A4 24 6 16 16 17 13 14 20 21 A3 22 23 9 20 25 250 FRAME PUMPS Ref Part No Part Description Qty 1 28012D000 MOTOR HOUSING 1 2 27966D010 BEARING HOUSING 1 3 27882A009 TERMINAL BLOCK 1 4 06106A069 SCREW CAP SKT HD 2 5 110650043 SCREEN 1 6 19331A009 WASHER SPRI...

Страница 9: ...1 005700181 005700181 005680191 D7 SCREW MACHINE NOT SHOWN SEE VOLUTE ASSY 008290061 3 008290061 3 N A SEE VOLUTE ASSY SEE VOLUTE ASSY 008290091 4 SEE VOLUTE ASSY N A D8 WEAR RING SEE VOLUTE ASSY 136900003 136900003 N A SEE VOLUTE ASSY SEE VOLUTE ASSY 136900003 SEE VOLUTE ASSY N A D9 CUTTER PLATE N A N A N A N A N A N A N A N A 153600002 D10 CUTTER INSERT N A N A N A N A N A N A N A N A 153320014 ...

Страница 10: ...A027 A4 SPACER 076650041 076650041 076650041 076650121 076650121 076650121 CONNECTOR 12672A001 12672A001 ITEM 8 POLE 870 RPM 10 15 HP 10 15 HP 10 15 HP 208 230 3 60 460 3 60 575 3 60 A1 STATOR 27963D003 27963D003 27963D603 A2 ROTOR SHAFT ASSEMBLY 27963D011 27963D011 27963D011 A3 BOLT STATOR 4 005560081 005560081 005560081 A4 SPACER 076651001 076651001 076651001 CONNECTOR 12672A001 ITEM 6 POLE 1150...

Страница 11: ...8 110430382 S4LV X P4000FC 40 460 3 6 4 11 5 110430012 S4LV X P4000GC 40 575 3 8 4 11 5 110430012 1150 RPM S4LV X P750DB 7 5 208 3 8 4 10 110430042 S4LV X P750EB 7 5 230 3 8 4 10 110430042 S4LV X P750FB 7 5 460 3 10 4 10 110430042 S4LV X P750GB 7 5 575 3 10 4 10 110430042 S4LV X P1000DB 10 208 3 8 4 11 25 110430082 S4LV X P1000EB 10 230 3 8 4 11 25 110430082 S4LV X P1000FB 10 460 3 10 4 11 25 1104...

Страница 12: ...025940002 S4L X P750FA 7 5 460 3 10 4 11 88 025940002 S4L X P750GA 7 5 575 3 10 4 11 88 025940002 S6L X P Cat No HP Volt Ph Cord Trim Impeller 1750 RPM S6L X P2000DC 20 208 3 6 4 9 88 025940372 S6L X P2000EC 20 230 3 6 4 9 88 025940372 S6L X P2000FC 20 460 3 8 4 9 88 025940372 S6L X P2000GC 20 575 3 8 4 9 88 025940372 S6L X P2500DC 25 208 3 4 4 10 25 025940072 S6L X P2500EC 25 230 3 6 4 10 25 0259...

Страница 13: ... P2500FC 25 460 3 8 4 10 13 025940172 S8F X P2500GC 25 575 3 8 4 10 13 025940172 S8F X P3000EC 30 230 3 4 4 10 5 025940082 S8F X P3000FC 30 460 3 8 4 10 5 025940082 S8F X P3000GC 30 575 3 8 4 10 5 025940082 S8F X P4000FC 40 460 3 6 4 11 38 025940202 S8F X P4000GC 40 575 3 8 4 11 38 025940202 1150 RPM S8F X P750DB 7 5 208 3 8 4 10 38 025940162 S8F X P750EB 7 5 230 3 8 4 10 38 025940162 S8F X P750FB...

Страница 14: ...20 460 3 8 4 12 136920012 S4B X P2000GB 20 575 3 10 4 12 136920012 870 RPM S4B X P1000DA 10 208 3 8 4 12 136920012 S4B X P1000EA 10 230 3 8 4 12 136920012 S4B X P1000FA 10 460 3 10 4 12 136920012 S4B X P1000GA 10 575 3 10 4 12 136920012 S4LV X P CAT NO HP VOLT PH CORD TRIM IMPELLER 1750 RPM S4LV X P5000FC 50 460 3 4 4 12 110430002 S4LV X P5000GC 50 575 3 6 4 12 110430002 S6A X P CAT NO HP VOLT PH ...

Страница 15: ...15 E 03 558 07 05 20 WIRINGDIAGRAMS ...

Страница 16: ...ll dual seal pumps Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor travel expenses rented equipment removal reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility This limited warranty will not apply a to defects or malfunctions resulting from failure to properly install operate or main tain the...

Отзывы: