REGULATION INSTRUCTIONS
32
P
ARAMETER
17
–
M
INIMUM
F
AN
S
PEED
S
ETTING
6. Use buttons „+‟ o „-‟ to modify the value of the parameter between:
min = 33 Hz ; max = value of parameter 18
The default value is :
- 38 Hz for Natural Gas;
- 50 Hz for L.P.G.;
7. Press and release button „S‟ to confirm. The parameter number
(17) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
18
–
M
AXIMUM
F
AN
S
PEED
S
ETTING
6. Use buttons „+‟ o „-‟ to modify the value of the parameter between:
min = value of parameter 17; max = 202 Hz.
The default value is:
- 185 Hz for Natural Gas;
- 183 Hz for L.P.G.;
7. Press and release button „S‟ to confirm. The parameter number
(18) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
19
–
M
INIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons „+‟ o „-‟ to modify the value of the parameter between:
min = 33 ; max = value of parameter 18.
The default value is:
- 38 Hz for Natural Gas;
- 50 Hz for L.P.G.;
7
.
Press and release button „S‟ to confirm. The parameter number
(19) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
20
–
M
AXIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons „+‟ o „-‟ to modify the value of the parameter between:
min = value of parameter 17; max = 202 Hz.
The default value is:
- 145 Hz for Natural Gas;
- 143 Hz for L.P.G.;
7
.
Press and release button „S‟ to confirm. The parameter number
(20) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
S
S
P 17
055
P 20
164
P 19
055
S
S
164
P 18
S
S
S
S
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz
110V 60Hz