WARNING
WARNING
Bathing Procedure
System Prep-Entering Spa-Bathing
760750 Rev A
Only personnel who have thorough knowledge and have read
this manual should operate the Dream Spa. Operation of this
equipment by unknowledgeable personnel could result in injury
to the operator or patient. Your Penner Patient Care distributor is
available to answer any questions regarding the equipment’s
proper operation.
System Preparation (Before Bath)
Prior to the bath, perform the following preparation steps.
1. Make sure you have all of the bathing aids ready for the resident such as bath oil, shampoo, washcloth, and towels.
Entering the bath
The resident is now ready to enter the bath. To do so:
1. Make sure the bathing area is clear of all unneeded equipment
2. If desired, turn on the heated back and seat by pushing the Heated Seat Control Button. It will take the heated back
and seat approximately 8 minutes until heat radiates through the spa. The heat will automatically shut off after 30
minutes.
3. Open the door to the widest available position.
4. The resident should sit on the seat first then swing his/her legs into the bath.
5. While the resident is seated, place the provided seat belt around the resident and comfortably tighten. (Not available
for residential models)
6. Close the door and move the lever forward or towards the front of the spa until it stops to fully lock into place.
7. The spa is now sealed and ready to be filled with water.
Stepping into the spa first and then sitting on the seat may put the resident in danger of
slipping and cause harm to the resident and/or staff.
Bathing Procedure
1. Place the drain plug in the drain
2. Start the air blower by pressing the Aqua-Aire ON/OFF button shown on the controls page to allow warm air to
circulate around the resident while the spa is filling. The blower has 3 speeds. Pressing the button once will give
you the maximum water movement. Twice will be medium water movement and the third time will give you
minimal water movement. Fourth push will shut the Aqua-Aire off.
3. Turn the hot and cold water handles on to mix the proper temperature of water for the bath typically between 95-
105 degrees Fahrenheit.
4. Monitor the water temperature by watching the incoming water temperature read-out. Adjust the water
temperature by turning the hot and cold water handles to a normal bathing temperature, 95 to 105 degrees
Fahrenheit.
5. When filled, turn the hot and cold water handles to the off position.
6
1-800-732-0717
www.pennerbathing.com