Mounting Pedestal

The 12” high mounting pedestal, available in aluminum or galvanized steel, incorporates a removable access panel for easy inspection 

and service of motor operated backdraft dampers. It provides solid ventilator support and a weather resistant seal that does not injure or 

disturb flashing. This item should not be used with Fatrap units.

Hinged Sub-Base

Hinged sub-bases provide access to the curb well for damper service or the clean out for grease applications. Constructed with a rust 

proof hinge arrangement and low height, (3 ½”) the assembly is easily manipulated and reduces the impact on overall installation height. 

This accessory is available for use with most models for either factory built or existing roof curbs.

Aluminum Bird & Insect Screen

Bird screens are available for all direct and belt drive models. An aluminum insect screen with a smaller mesh than the standard bird 

screen is also available. However, please note that NFPA 96 installations do not allow the use of bird or insect screens. The requirements 

of local codes must be reviewed to determine if there are any conflicts.

Internal Wiring

NEMA 3R wiring is available for both direct and belt drive models.

Backdraft Dampers

Backdraft dampers are available for either gravity or motorized operation (motor kit optional). Dampers feature square galvanized steel 

frames and multi-leaf, roll formed aluminum blades with nylon bearings. Backdraft dampers should not be used when venting kitchen 

hoods. NFPA 96 installations do not allow the use of dampers. The requirements of local codes must be reviewed to determine if there 

are any conflicts.

Floating Hinge Kit

A floating hinge kit is also available for field installation. This assembly connects 

the exhauster directly to the roof curb and provides the same level of access as 

the hinged sub-base.

Safety Service Switch

Safety service switches are available to allow positive  electrical  shut-off and 

safety.  Switches are factory mounted when factory wiring is requested. Wiring 

is  only  run  from  the  motor  to  the  junction  box.  (Factory  wiring  of  explosion 

proof applications is not available.) A wide range of NEMA rated enclosures 

with service switches are available  for indoor, outdoor, and explosion proof 

installations. Service switches are to be field wired by a licensed electrician.

OPTIONS & ACCESSORIES

Fumex

Base

Floating Hinge Plate

Bushing

Back Plate

(Inside Curb/Pedestal)

Ventilator

Curb/Pedestal

Firestat Switch

Firestat switch automatically disconnects the unit when the temperature of the 

air being exhausted exceeds a preset rating.

Содержание Fumex

Страница 1: ...Upblast Roof Exhausters FUMEX PennBarry Your Single Source for Commercial Industrial Supply Exhaust Fans www pennbarry com PRODUCT GUIDE...

Страница 2: ...y com 2 TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS LISTINGS 4 FEATURES BENEFITS 5 6 OPTIONS ACCESSORIES 7 12 MOTOR AVAILABILITY 13 14 DIRECT DRIVE DIMENSIONS 15 BELT DRIVE DIMENSIONS 16 FAN SELEC...

Страница 3: ...es Fumex fans feature a weather resistant seamless spun aluminum housing which provides ample drainage and works in conjunction with a patented wheel design and deeply spun inlets to provide smooth qu...

Страница 4: ...Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program FX27B is not AMCA Certified cULus Certification Fumex fans carry the UL label UL705 ZACT ZACT...

Страница 5: ...ts Vibration Isolators Multidirectional rubber in shear vibration isolators mitigate residual vibration transmission from the unit to the building Structural Integrity Durable housings of spun aluminu...

Страница 6: ...rect Drives These enhanced units have Gplus motor selection up to 2 HP available on single phase and three phase and are available up to size 24 Design enhancements to Direct Drive Fumex models signif...

Страница 7: ...cy By varying the fan motor input frequency and voltage the VFD controls the motor speed and torque helping to improve productivity and lower energy consumption The VSC and VSA are ideal for both new...

Страница 8: ...lt drive models Backdraft Dampers Backdraft dampers are available for either gravity or motorized operation motor kit optional Dampers feature square galvanized steel frames and multi leaf roll formed...

Страница 9: ...is constructed from 10 gage galvanized steel and incorporates five torsion springs to automatically position the motor and maintain proper belt tension Additional benefits include reduced belt and pul...

Страница 10: ...28 5 27 35 20 19 75 18 FX18BH 28 5 27 35 20 19 75 18 FX24B 33 5 32 40 25 24 75 18 FX24BH 33 5 32 40 25 24 75 18 FX27B and FX30B 36 5 35 43 28 27 75 18 FX36B 44 5 43 51 36 35 5 18 Standard heights H a...

Страница 11: ...o the housing exterior An appropriately sized service switch is commonly selected as an additional option These items meet the code requirements for positive electric shut off Grease Collector Separat...

Страница 12: ...he additional 45 minutes at 1000 F will buy precious time in the event of a fire Steel Wheel The wheel is a standard duty all welded wheel standard duty and high pressure belt drive The blades are cur...

Страница 13: ...ally the Green Plus can accept 0 10V input to tie to building management systems not only allowing for savings in direct fan energy consumption but reducing the exhaust of conditioned air during off p...

Страница 14: ...erter rated motors suitable for use with variable frequency drives can be supplied for belt drive models Contact your local PennBarry representative for availability Available Lek Trol Speed Controls...

Страница 15: ...1 8 18 1 2 11 1 2 16 7 8 24 16 Gauge 0 064 0 050 32 42 lbs 1 FX13 25 1 2 16 1 2 18 1 2 11 1 2 17 7 8 24 16 Gauge 0 064 0 050 45lbs 2 FX16 30 1 4 22 3 8 20 1 2 16 24 24 1 4 16 Gauge 0 064 0 064 69lbs 3...

Страница 16: ...44 1 2 5 1 2 470 6 All dimensions are in inches 1 Add 8 lbs for Heat and Smoke option 2 Add 11 lbs for Heat and Smoke option 3 Add 20 lbs for Heat and Smoke option 4 Add 55 lbs for Heat and Smoke opt...

Страница 17: ...20 00 20 25 00 25 X Special Motors and Drives F Factory mounted L Less motor less drive M Less motor with drive Motor Enclosure 0 None 1 TE w Overload 2 TE w o Overload 3 ODP w Overload 4 ODP w o Over...

Страница 18: ...al 0 None A Galvanized pedestal B Galvanized vented pedestal C Aluminum pedestal D Aluminum vented pedestal Spare Belt s 0 None 1 1 spare set 2 2 spare set Special Applications 0 None 2 Restaurant exh...

Страница 19: ...Exhaust fans Outdoor units Indoor units PENNBARRY PRODUCT SOLUTIONS PennBarry www pennbarry com pennbarrysales pennbarry com Tel 972 212 4700 Fax 972 212 4702 PennBarry reserves the right to make cha...

Отзывы: