PennBarry Fumex Скачать руководство пользователя страница 12

www.PennBarry.com 

12

OPTIONS & ACCESSORIES

Product Certifications:

18)  Miami-Dade NOA # 14-0311.03
19)  Florida Product Approval #12339
20)  Texas Department of Insurance # RV-48

Belt Drive Fumex Cutaway

Direct Drive Fumex Cutaway

Heat & Smoke Removal Configuration

While Fumex fans are commonly used for general ventilation, they are also designed to discharge contaminated or grease-laden air 

or fumes up and away from building surfaces with the Fatrap option. When equipped with the Heat and Smoke Removal option, this 

series of fans incorporates features exclusively designed to exhaust heat and smoke in the event of fire. During these emergencies, the 

fans are designed to operate at the temperature and time limits stated below. To maintain power to these fans during emergencies, 

special consideration must be made for field power supply. In the event of an emergency, if power is maintained, the units will operate 

for the times and temperatures indicated, after which they will continue to operate until they are destroyed by the extreme temperature 

generated during an actual fire, or their roof structure collapses.

For smoke control systems, Heat and Smoke Removal configured fans are listed per UL for emergency smoke removal, referencing UL705, 

UL793, Industrial Risk Insurers (IRI), and Southern Building Code Congress International (SBCCI).

The UL standard requires the fan to run at 500°F for 4 hours (IRI) and 1000°F for 15 minutes (SBCCI). PennBarry Heat and Smoke Removal 

configured Fumex units are listed at 500°F for 4 hours and 1000°F for 1 hour. The additional 45 minutes at 1000°F will buy precious time 

in the event of a fire.

Steel Wheel: The wheel is a standard duty, all-welded wheel (standard duty and high pressure belt drive). The blades are curved for 

improved air performance while increasing their strength and rigidity. The wheel assembly is fully welded to provide extremely durable 

and consistent performance. The wheel is dynamically balanced. Balancing weights are mechanically attached to the inside of the rims 

of both the backplate and wheel inlet. This allows a precise placement of the weights anywhere within a full 360° range on two separate 

planes, without the possibility of detachment.

Forced Motor Cooling: Motors and drive components are located out of the airstream in a separate compartment. Two cooling tubes 

are located between the motor dome and discharge apron which enables fresh air to be drawn into the motor compartment during fan 

operation. This allows the cooler outside air to wash over the motor and bearings. This positive cooling promotes longer life for the motor 

and drive components.

High Wind Construction

High wind construction Fumex fans are specifically designed for high wind hurricane zones (HWHZ). The Fumex models are designed 

to withstand 150 MPH winds in accordance with Miami-Dade and Florida Building Code standards. The units are 3rd party tested and 

certified through a 3rd party Professional Engineer (P.E.) to meet these strict standards. Installation details are provided and since there are 

no tie downs or external braces required for attaching the unit to the roof or curb this makes installation simple and easy. A wide range 

is offered to meet all of your ventilation needs which includes all belt and direct drive sizes 36 and under.

Содержание Fumex

Страница 1: ...Upblast Roof Exhausters FUMEX PennBarry Your Single Source for Commercial Industrial Supply Exhaust Fans www pennbarry com PRODUCT GUIDE...

Страница 2: ...y com 2 TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS LISTINGS 4 FEATURES BENEFITS 5 6 OPTIONS ACCESSORIES 7 12 MOTOR AVAILABILITY 13 14 DIRECT DRIVE DIMENSIONS 15 BELT DRIVE DIMENSIONS 16 FAN SELEC...

Страница 3: ...es Fumex fans feature a weather resistant seamless spun aluminum housing which provides ample drainage and works in conjunction with a patented wheel design and deeply spun inlets to provide smooth qu...

Страница 4: ...Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program FX27B is not AMCA Certified cULus Certification Fumex fans carry the UL label UL705 ZACT ZACT...

Страница 5: ...ts Vibration Isolators Multidirectional rubber in shear vibration isolators mitigate residual vibration transmission from the unit to the building Structural Integrity Durable housings of spun aluminu...

Страница 6: ...rect Drives These enhanced units have Gplus motor selection up to 2 HP available on single phase and three phase and are available up to size 24 Design enhancements to Direct Drive Fumex models signif...

Страница 7: ...cy By varying the fan motor input frequency and voltage the VFD controls the motor speed and torque helping to improve productivity and lower energy consumption The VSC and VSA are ideal for both new...

Страница 8: ...lt drive models Backdraft Dampers Backdraft dampers are available for either gravity or motorized operation motor kit optional Dampers feature square galvanized steel frames and multi leaf roll formed...

Страница 9: ...is constructed from 10 gage galvanized steel and incorporates five torsion springs to automatically position the motor and maintain proper belt tension Additional benefits include reduced belt and pul...

Страница 10: ...28 5 27 35 20 19 75 18 FX18BH 28 5 27 35 20 19 75 18 FX24B 33 5 32 40 25 24 75 18 FX24BH 33 5 32 40 25 24 75 18 FX27B and FX30B 36 5 35 43 28 27 75 18 FX36B 44 5 43 51 36 35 5 18 Standard heights H a...

Страница 11: ...o the housing exterior An appropriately sized service switch is commonly selected as an additional option These items meet the code requirements for positive electric shut off Grease Collector Separat...

Страница 12: ...he additional 45 minutes at 1000 F will buy precious time in the event of a fire Steel Wheel The wheel is a standard duty all welded wheel standard duty and high pressure belt drive The blades are cur...

Страница 13: ...ally the Green Plus can accept 0 10V input to tie to building management systems not only allowing for savings in direct fan energy consumption but reducing the exhaust of conditioned air during off p...

Страница 14: ...erter rated motors suitable for use with variable frequency drives can be supplied for belt drive models Contact your local PennBarry representative for availability Available Lek Trol Speed Controls...

Страница 15: ...1 8 18 1 2 11 1 2 16 7 8 24 16 Gauge 0 064 0 050 32 42 lbs 1 FX13 25 1 2 16 1 2 18 1 2 11 1 2 17 7 8 24 16 Gauge 0 064 0 050 45lbs 2 FX16 30 1 4 22 3 8 20 1 2 16 24 24 1 4 16 Gauge 0 064 0 064 69lbs 3...

Страница 16: ...44 1 2 5 1 2 470 6 All dimensions are in inches 1 Add 8 lbs for Heat and Smoke option 2 Add 11 lbs for Heat and Smoke option 3 Add 20 lbs for Heat and Smoke option 4 Add 55 lbs for Heat and Smoke opt...

Страница 17: ...20 00 20 25 00 25 X Special Motors and Drives F Factory mounted L Less motor less drive M Less motor with drive Motor Enclosure 0 None 1 TE w Overload 2 TE w o Overload 3 ODP w Overload 4 ODP w o Over...

Страница 18: ...al 0 None A Galvanized pedestal B Galvanized vented pedestal C Aluminum pedestal D Aluminum vented pedestal Spare Belt s 0 None 1 1 spare set 2 2 spare set Special Applications 0 None 2 Restaurant exh...

Страница 19: ...Exhaust fans Outdoor units Indoor units PENNBARRY PRODUCT SOLUTIONS PennBarry www pennbarry com pennbarrysales pennbarry com Tel 972 212 4700 Fax 972 212 4702 PennBarry reserves the right to make cha...

Отзывы: