Advanced Settings
Parameters that can be changed are indicated with orange font. To change a parameter,
tap on the orange font then use the keyboard that appears to change the value.
1.
Regeneration Day Override:
Adjust this parameter to every 14 days. If the system
will be down more than two weeks at times, set the unit to 10 days.
2.
Reserve Capacity:
Adjust the reserve capacity to 10% for 1-3 people in the home.
Set to 25% for 4+ people in the home.
3.
Resin Grains:
Adjust this as follows:
Model
Grains Cap
Brine Fill
080-PWXH-150
24,000
4 mins.
080-PWXH-250
36,000
6 mins.
080-PWXH-300
48,000
8 mins.
4.
Backwash:
This should be set to "10" mins and should not be changed.
5.
Brine Draw/Slow Rinse:
This should be set to "60" mins and should not be
changed.
6.
Rapid Rinse:
This should be set to "10" mins and should not be changed.
7.
Brine Refill:
See table above for proper brine refill mins.