Pelonis KCD25Y1 Скачать руководство пользователя страница 7

Key Pad Functions

Fig.5

I/O:

Power On/Off.

MODE:

Selects the appropriate operating mode.

(Dehumidifier)

.

Cool-Heat-Dry

-Fan

Note:

"Heat Mode" is for Heating/Cooling Model

only .

MODE Indicator Lights:

Illuminates under the

different mode settings Fig.6;

COOL Mode:

Green Light

HEAT Mode:

Red light

DRY(Dehumidifier)Mode:

Green Light

FAN Mode:

No indicator light

Remains on while compressor is

Green Light :

operating. Green light turns off when desired

temperature is achieved.

Applicable to both

Air Conditioner and Dehumidifier.

Red Light:

Remains on while heater is

operating. Red light turns off when desired

temperature is achieved.

Water Full Indicator Light:

Flashes red when

the water level of the water tank exceeds the

maximum set level or if the water tank is not

correctly positioned in the cabinet. Fig.7.

Selects High-Medium-Low fan speeds

FAN:

Fan Options:

Cooling (3 speeds)

High-Medium-LOW.

Heating (2 speeds)

High-Low.

Dry-Dehumidifying (1 speed)

Medium.

Fan (3 speeds)

High-Medium-Low.

: Used to adjust (forward ) Time of Day Clock

: Used to adjust (backward ) Time of Day Clock

settings (1min, increments).

settings (1min, increments).

Used to adjust (forward) Temperature

Used to adjust (backward) Temperature

settings (1 C increments).

o

settings (1 C increments).

o

Used to adjust (forward) Auto-Timer of settings

Used to adjust (backward) Auto-Timer of settings

(10 min. increments)

(10 min. increments)

SWING:

CLOCK: Allows you

TIME OF DAY

Allows the vertical louver grills

to oscillate back and forth automatically(70 Swing).

to initiate and/or change the

setting.

o

TIMER ON:

Used to initiate the AUTO ON start time

program, in conjuction with the

&

key pads

TIMER OFF:

AUTO OFF

Used to initiate the

stop time

program, in conjuction with the

&

key pads.

I/O

FAN

SWING

MODE

ON

TIMER

OFF

CLOCK

Fig.5

Fig.6

Fig.7

Cool/Heat/Dry

Water Full

Green light while cooling

Red light while heating

Green light while dehumidifying

A warning signal of 8 beeps will
sound and the Water Full
indicator will flash every
0.5 seconds.

Temperature Conversion Chart

O

O

C

10 11 12 13 14 15 16 17 18 19 20 21

F

50 52 54 55 57 59 61 63 64 66 68 70

O

O

C

22 23 24 25 26 27 28 29 30 31 32 33

F

72 73 75 77 79 81 82 84 86 88 90 91

6

Содержание KCD25Y1

Страница 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL Read Rules for Safe Operation and Instructions Carefully...

Страница 2: ......

Страница 3: ...leave this unit unattended in a space where people or animals who cannot react to a failed unit are located A failed unit can cause extreme overheating or death in such an enclosed unattended space CA...

Страница 4: ...d or servicing Electrical Specifications Unit Specifications Power Consumption Cooling Capacity Heating Capacity Dehumidifying Capacity Noise Level Power Source Refrigerant Water Tank Capacity Unit We...

Страница 5: ...r the mode There should be at least 11 8 30 cm clearance between the unit and any other other objects or building structure The unit should be installed on a level surface The window kit does not have...

Страница 6: ...the cabinet otherwise the unit will not operate Fig 4 5 To turn the unit on press the key On Off Switch Water Tank Safety Feature FULL 8 BEEPS WATER FULL This unit is equipped with a fail safe switch...

Страница 7: ...adjust forward Time of Day Clock Used to adjust backward Time of Day Clock settings 1min increments settings 1min increments Used to adjust forward Temperature Used to adjust backward Temperature set...

Страница 8: ...clock program In the event this should happen you will be required to re set the clock program 1 Install the Fig 10 and the as depicted in Fig 2 2a 2b pg 5 2 Press the I O on off key pad to switch on...

Страница 9: ...perature level The temperature has no effect on the fan operation Therefore the fan will operate continuously after the compressor has cycled off to maintain optimal temperature control 12 00 00 TIMER...

Страница 10: ...cannot select a fan speed The fan motor operates at a pre set speed which registers as in the window 4 Condensed water will be accumulated in the water tank When the tank is full the unit will sound...

Страница 11: ...nk when re locating your unit to a location room where continuous draining is not possible drain hose the internal drain hose and or leave Fig 19 Garden Hose not included Drain Hose Connector 10 Durin...

Страница 12: ...the key to activate the automatic air swing oscillating feature the air swing symbol will appear in the window Fig 23 To deactivate the air swing feature press the key again 5 To adjust air flow direc...

Страница 13: ...ection will be displayed in the window Each depression of the fan key will advance to a different speed 4 Press the key to activate the automatic air swing oscillating feature the air swing symbol wil...

Страница 14: ...ridden and or canceled Any interruption to the electrical power supply of the unit automatically cancels erases all auto timed programs In the event this should happen you will be required to re set y...

Страница 15: ...ime Fig 32a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is established the time will flash in the display w...

Страница 16: ...he or key pad to select the desired start Fig 33a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is establishe...

Страница 17: ...d to select the desired time Fig 32a Key pad will decrease the setting in 10 minute increments Key pad will decrease the setting in 10 minute increments When the desired time is established the time w...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ...ull the filter out then up Fig 34 3 Dust Dirt clogged in the filter can be removed by vacuum cleaning the soiled areas 4 The filter can also be washed in lukewarm soapy water while rubbing it lightly...

Отзывы: