TYING MACHINE FIXION 2
29_133084-G
7. INCIDENTS AND TROUBLESHOOTING
7.1. SUMMARY OF CHARGE INDICATOR AND BEEP MESSAGES
Normal messages
Use
fixed
Battery charge level (0 to 99)
with 1 beep per minute
Battery empty, recharge immediately
flashing with 1 beep every 10 seconds
Stop using, recharge immediately
Charging
flashing every 4 seconds
Battery charge level (0 to 99)
fixed
Charging complete
Storage
flashing
Auto discharge indicator after 10 days unused (final
threshold <30%).
Degraded mode messages
Use
and alternately
Stop the tool; the battery temperature is too high
1 long beep and 1 short beep
Stop the tool: current too high
1 long beep and 4 short beeps
Stop the tool; the tool temperature is too high
Charging
and alternately
Charge interrupted: Battery temperature too low
and alternately
Charge interrupted: Battery temperature too high
Fault messages
Use
and 1 beep every 2 minutes for 24 hours
Voltage too low after 3 hours of non-use. Recharge bat-
tery immediately
Charging
and alternating and continuous beep
Battery problem
and alternately
Charger problem
7.2. TYING MACHINE AND INTEGRATED BATTERY
If your tool no longer works:
1. Turn off the tool with the off button (power indicator light off).
2. Check the battery is charged, as shown on the gauge display.
3. Check that nothing is blocking the passage of the tie: Repeat the procedure in the Section 5.7, “End of the
tie band spool”.
4. Clean the tool (see Section 6, “Maintenance”).
5. Turn on the tool with the on button (power indicator light on).
6. Press the trigger.
7. If the tool does not work, return the complete equipment in its original packaging to a certified repair service.
37
Содержание FIXION 2
Страница 2: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...PELLENC Quartier Notre Dame 84120 Pertuis France...