BACKPACK BLOWER AIRION BP
57_148610-A
Symptoms
State of the on/off switch of the battery
HMI screen
Probable cause
Checks
Solutions
Repairer
Blocked air in- take screen
Check the condition of the air intake screen
Clean or re- place the air intake screen
User or Pel- lenc autho-
rised distributor
Dirty or damaged rotor
Check the condi- tion of the rotor
Clean or re- place the rotor
User or Pel- lenc autho-
rised distributor
Air flow duct obstruct-
ed or blocked (an-
gled air intake , blow- er tube, nozzle, etc.)
Check the condi- tion of the duct and the air intake screen
Clean the air intake screen
User
The auxiliary nozzle is holed or broken
Check the condition of the auxiliary nozzle
Change the aux-
iliary nozzle
User or Pel- lenc autho-
rised distributor
Loss of efficien- cy of the air flow
On
On
The auxiliary nozzle of the nozzle tip are not properly locked in place
Check the condition of the auxiliary noz- zle and/or nozzle tip
Lock the auxil- iary nozzle and / or the nozzle tip
User
7.2. SUMMARY OF DISPLAY SCREEN MESSAGES
Fault messages appear on the HMI screen of the tool.
43