1/2 inch ISO 228
(straight)
1/2 inch EN 10226-1
(conical)
25
3 Position and arrangement
24
3 Position and arrangement
3.1 Installation
Install the hob on a flat, stable and horizontal base.
•
Keep a free space of at least 2 cm around the hob.
•
Do not place any inflammable or deformable objects directly beneath the hob.
•
3.2 Gas connection
The fitting of the appliance should only be carried out by
•
a registered Corgi gas fitter.
Please note:
•
the type of gas and the country for which
the appliance has been designed are indicated on the
ratings plate.
This is a category 1 appliance.
•
The gas connection must comply with national and local
•
regulations.
A safety hose should be approved and suitable for the
•
type of gas for which the appliance is adjusted see
rating plate).
The safety hose should not be longer than 2 meter.
•
•
Please note:
a safety hose may not be bent and must not come into contact with
moving parts of kitchen units.
Please note:
•
a safety hose should not be above the appliance due to the fact that
the flames of the burners could damage the hose.
•
In all cases the connection tap for the appliance must be
•
positioned such that it is easily accessible.
before using the appliance for the first time check the
•
connections using water and washing-up liquid to ensure
that there are no gas leaks.
Please note:
•
the bottom of the hob becomes hot.
3.3 Electrical connection*
230 V - 50 Hz - 1,1 VA
The electrical connection must comply with national and local regulations.
•
Wall socket and plug must be accessible at all times.
•
If you want to make a fixed connection, ensure that a multi-pole switch with a
•
distance between contacts of 3 mm is installed in the supply cable.
Put the plug into the socket.
•
Make sure that the lead does not come into contact with parts that become hot.
•
Please note:
•
this appliance must be earthed.
If the connecting cable is damaged, it may only be replaced by the manufacturer,
•
the manufacturer’s service organisation or equivalently qualified persons, in order to
avoid dangerous situations.
Category
I2L
Gas type and pressure
G25 / 25 mbar
Country of destination
NL
Nominal heat input total
7,5 kW
Nominal heat input rapid burner
3,0 kW
Nominal heat input semi-rapid burner
1,75 kW
Nominal heat input simmer burner
1,0 kW
* Only for gas hobs with spark ignition: PK454 and PK554
Содержание PK354