125
installation
Building in
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately (see
table). Also saw out any partitions that may be present. The distance from the
saw line to the rear wall and/or side wall is indicated in the table.
Table:
Space to be left free around the appliance:
Type of hob
IDK640
Appliance width x depth
604 x 512 mm
Installation height from top of worktop
48 mm
Cut out dimensions width x depth
560 x 490 mm
Distance from saw line to rear wall
Minimaal 50 mm
Distance from saw line to side wall
Minimaal 50 mm
min. 600 mm
min. 650 mm
min. 450 mm
min. 40 mm
cooker hood
cabinet
side wall
Ceramic hob
min. 40 mm
604
512
48
560
490
min.50
124
installation
The next deviant connections are possible too:
1 phase connection
1 po 1 negative 1N a.c. 230 V
The fuse box in your home must be fitted with a 32 A fuse.
3 phase connection
3 positive without negative 3 a.c. 230 V
The fuse box in your home must be fitted with a 16 A fuse.
Safety prescriptions
For the appliance to work well, it is important:
■
That there is sufficient ventilation to allow the hob to cool down, in
accordance with the possibilities specified in this chapter.
■
The ventilation air drawn in by the hob must not be warmer than 35 °C. Bear
this in mind if the oven is to be built in under the hob.
■
That the connecting cable hangs freely and is not caught by a drawer.
■
The worktop should be a minimum of 2.8 cm and a maximum of 5 cm thick.
■
The worktop is flat.
N
L
230V
b
lue
b
rown
g
rey
b
lack
yellow/
g
reen
negative connection N (blue and
brown)
positive connection L (grey and
black)
L3
L2
L1
230V
230V
230V
b
lue
b
rown
g
rey
b
lack
yellow/
g
reen
positive connection L1 (grey)
positive connection L2 (black)
positive connection L3 (blue and
brown)