INSTALLATION INSTRUCTIONS (cont.) 

ELECTRICAL CONNECTIONS 

 

 
.  

WARNING: This appliance must  be earthed. 
 If in any doubt consult a competent person. 

If the plug supplied is not suitable for the socket outlet, or if the 
appliance is to be connected to fixed wiring, it should be cut  from 
the supply cord and disposed of immediately.  If the severed plug 
is introduced  into a live socket outlet there is a risk of electric 
shock.  

If the power cable is damaged in any way, it must be replaced.  
Replacements are available from your main supplier or dealer. 

NOTE: Should the plug need to be replaced for any reason, the 
wires in the mains lead are coloured in accordance with the fol-
lowing code: 
Green and Yellow:          Earth 
Blue:                               Neutral 
Brown:                            Live 
The wire coloured green and yellow must be connected to the 
terminal marked with the letter ‘E’ or by the earth symbol =,or 
coloured green and yellow.  The wire coloured blue must be con-
nected to the terminal ’N’ or coloured black.  The wire coloured 
brown must be connected to the terminal marked ‘L’ or coloured 
red.  If the fuse incorporated in the plug needs to changed then it 
should be replaced with a fuse approved by ASTA to BS1362, 
rated at 10 A. 

The power cord must be long enough to allow for the removal of 
the upper service module should any repair or maintenance work 
be required.

 

The cabinet is supplied ready for connection to the power supply 
with a UK style three pin plug complete with a 10 A fuse.   
 
The power supply rated at 220- 240volt, 50-60 Hz. 
The power cable is approx. 1.8m  in length. 
 
The plug (and socket outlet) should be in an accessible position 
for ease of removal. 
 
An alternative arrangement could be a high level  fused outlet 
plate with a separate switch conveniently located at a lower level. 

Содержание ETS-1500

Страница 1: ...Installation and Operating Manual Drying Cabinet Model ETS 1500...

Страница 2: ...and or changes to the cabinet and to the contents of this manual Origination 01 2008 Revised 05 11 UK version DATA PLATE DETAILS This manual describes the cabinets functions and operation and include...

Страница 3: ...designed to eliminate static unless recommended by the manufacturer Do not use heat to dry articles containing foam rubber or similar textured rubberised materials To dry this type of material use th...

Страница 4: ...Check that the goods have not been dam aged in transit Any damage should be recorded on the delivery note and reported to your dealer within 3 days Check that all restraining tape and protective poly...

Страница 5: ...This can be achieved without removing the lower control module 6 5 Remove the lower white plastic guide plug on the unused hinge bracket and refit to the opposite side 6 Refit the lower hinge pin to...

Страница 6: ...hing machine or tumble dryer to ensure that the cabinet is insulated from any vibrations that may occur when these machines are in operation This will also ensure that the machines can be removed shou...

Страница 7: ...1 CONNECTION TO AN EXISTING SYSTEM 2 DIRECT CONNECTION TO OUTSIDE WALL Fit the plastic spigot to the outlet on top of the cabinet Core cut a 100mm diameter hole in the outside wall or alternatively c...

Страница 8: ...n and yellow must be connected to the terminal marked with the letter E or by the earth symbol or coloured green and yellow The wire coloured blue must be con nected to the terminal N or coloured blac...

Страница 9: ...t lay items flat on the up per hanging rail section Hang long clothing to the outer walls of the cabinet with shorter items to the centre Hang gloves scarves socks and small items on the hanging bars...

Страница 10: ...on circulates ambient temperature air only Rotating the switch position in a clock wise movement increases the heat input up to a maximum 1 5 kW The optimum setting is with the control set to the star...

Страница 11: ...m the cabinet as they become dry This will speed up the drying process for the remaining damp items OPERATING INSTRUCTIONS cont CARE CLEANING High pressure water jet cleaning should not used on this c...

Страница 12: ...OTE Replacement power cords should only be fitted by a qualified electrician NOTE Should the plug need to be re placed for any reason the wires in the mains lead are coloured in accordance with the fo...

Страница 13: ...general laundry textiles Electrical supply 230v 50Hz a c Motor 35W Heating element 1500W Overheat cut out Yes Timer 0 4 Hours Dimensions Height 1435mm Depth 610mm Width 595mm Weight 60kg SETTING POWE...

Страница 14: ...Page 14 Blank Page...

Страница 15: ...Installation and Operating Manual Page 15 Blank Page...

Страница 16: ...EQUIPMENT LIMITED Peko House Northbridge Road Berkhamsted Herts HP4 1GE Tel 01442 872323 Fax 01442 866900 www peko co uk...

Отзывы: