452-FUEPMF-Rev02_061002.pdf
GB - 2
Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de
126312-01
7.
Functional description of the transmitters
7.1 Two-button function (Function 1)
Button I switches consumers on and button O switches them
off. Standard function following the assigning of a transmitter!
7.2 One-button function (Function 2)
Activating either button I or button O will cause the consumer’s
state to toggle.
7.3 Momentary contact (Function 3)
The consumer will switch on when either button I or button O
is pressed and switch off again when the button is released.
7.4 Momentary contact with limited switch-on time
(Function 4)
The consumer will switch on when either button I or button O
is pressed. After an operating time of 10s or when releasing
the button the consumer is switched off.
7.5 Switch on with pulse time (Funktion 5)
The consumer will switch on with a pulse time of 2s when
either button I or button O is pressed.
Button
Function
Press button O
Switch off
Press button I
Switch on
Parameter
No adjustable parameters!
Button
Function
Press button I or button O
Switch on/off
Parameter
1
Button O is activated
2
Button I is activated
3
Button I and button O are activated
Button
Function
Press button I or button O
Switch on
Release button I or button O
Switch off
Parameter
1
Button O is activated
2
Button I is activated
3
Button I and button O are activated
Easyclick wall transmitter in Aura Design
Button I
Button O
Button I
Button O
8. Ranges between transmitters and receivers
The range of the Easyclick radio signals decreases as the
distance between transmitter and receiver increases.
If the normal range between transmitter and receiver is
insufficient, an Easyclick Repeater (453 FU RP o.T.) can
be employed to increase range.
The range between the transmitter and receiver in a house
is approx. 30m (line-of-sight connection) and 100m in halls.
The transmission range depends on the materials used
in the building:
Limiting the range of the radio signals due to:
• Installing the transmitter or receiver in the immediate vicinity
of materials with metal constituents, or metal objects.
A distance of at least 10 cm should be maintained.
• Installing the transmitter/receiver on the ground or at
ground level.
• Moisture in the materials
• Devices, which also emit high frequency signals, such as
e.g. computers, audio and video equipment, electronic
ballasts for illuminants.
A distance of at least 0.5m should be maintained.
9. Error analysis in the case of radio interference
For a new or pre-existing system:
• Check the system voltage of the receiver.
• Check if the receiver is receiving a radio command.
• Check if the receiver is connected as specified.
• Check the operation of the connected consumers.
• Delete all transmitters in the receiver, and reprogramme
the receiver.
• Check if any changes have been made around the system
that could generate problems (metal cabinets, walls or
furniture has been moved, etc.).
If possible, restore things to their original status.
• Mount the transmitter or receiver at a better location.
The receiver independently turns ON and OFF:
• This can occur when an outside transmitter is activated
within the receiver range that was previously programmed
in the receiver.
• Delete all transmitters in the receiver, and reprogramme
the receiver.
A transmitter does not work:
• Take the transmitter and move toward the receiver.
If the system still works at a closer distance, the transmitter
was installed outside of the transmission range, or there
was interference.
• Mount the transmitter or receiver at a better location.
10. Warranty
These operating instructions are an integral part of both the
appliance and the terms of warranty. They must be furnished
to the user. The technical design of the appliance is subject
to change without prior notification.
PEHA products are manufactured using state of the art tech-
nologies in compliance with prevailing national and internat-
ional regulations, and are quality tested.
If the product should, however, reveal any defects, PEHA
agrees to correct these defects without affecting the rights of
the end user to assert claims against the vendor arising from
the purchasing contract, as follows:
If the complaint is justified and properly filed, PEHA can choose
to either correct the defect or supply a functioning product.
Claims above and beyond this, or compensation for follow-
on damages are excluded. The appliance is deemed to be
justifiably defective when it is supplied to the end user in an
unusable or severely impaired state as a result of a design,
manufacturing or material error. The warranty does not apply
to natural wear and tear, improper use, incorrect connection,
interference with the appliance or external impacts.
The warranty period runs for 24 months from the purchase of
the appliance by the end user from a vendor, and expires at
the latest 36 months after manufacture of the appliance.
The settlement of warranty claims is subject to German law.
PEHA Easyclick products may be sold and used in EU
countries, Switzerland, Iceland and Norway.
The products conform to R&TTE Directive 1999/5/EC
and meet EU regulations.
Material
Typical range
Masonry
20m (max. 3 walls)
Reinforced concrete
10m (max. 1 wall/ceiling)
Drywall/wood
30m (max. 5 walls)
Button
Function
Press button I
Switch on with running time
(parameter)
Press button O
Switch off
Parameter
1
Running time 30 s
2
Running time 1 min
3
Running time 2 min
4
Running time 5 min
5
Running time 10 min
6
Running time 15 min
7
Running time 30 min
8
Running time 60 min
Button
Function
Press button I or button O
Switch on (max. 10s)
Release button I or button O Switch off
Parameter
1
Button O is activated
2
Button I is activated
3
Button I and button O are activated
7.6 Timer switching (Function 6)
Pressing button I will switch on the consumer for the preset
period of time (parameter).
Button O will switch off the consumer before timer timeout.
Button
Function
Press button I or button O Switch on with pulse
time (2s)
Parameter
1
Button O is activated
2
Button I is activated
3