17
BOILER DIMENSIONS & RATINGS
8. BOILER DIMENSIONS & RATINGS
Figure 8.1: Boiler Views
Table 7.1: Boiler Ratings
1 Boiler Model No. may have the following suffix letters: WPC = Water Package w/Burner & Circulator; WPCT = Water Package w/Burner,
Circulator & Tankless Coil.
2 Firing rate is based on a fuel oil with a heating value of 140,000 BTU per gallon. Burner input based on maximum altitude of 2,000 ft. – for other
altitudes consult factory.
3 Net water ratings based on an allowance of 1.15. Consult Factory before selecting a boiler for installations having unusual piping and pickup
requirements, such as intermittent system operation, extensive piping systems, etc.
4 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government test.
5 Must be used with factory supplied 4” flexible insulated venting system.
Series WV-DV™
Water
Content,
gal
Model
Number¹
Input²
Heating
Capacity
4
,
MBH
Net Ratings
Water
3
,
MBH
AFUE
4
,
%
GPH
MBH
WV-DV-03
0.75
105
92
80
86.7
11.75
WV-DV-04
1.15
161
141
122
86.7
14.75
WV-DV-04
1.30
182
158
137
86.0
14.75
Boiler
Model
Number
Jacket
Depth
“A”
Jacket
Width
“B”
Jacket
Height
“C”
Rear of Jacket
to c/l of Vent
“D”
Right Side of
Jacket to
c/l of Vent
“E”
Vent Size
Diameter
“F”
WVDV-03
14-1/8”
22-1/8”
35”
7-1/16”
8-5/16”
4”
WVDV-04
18-1/8”
22-1/8”
35”
9-1/16”
8-5/16”
4”
Содержание WV-DV Series