6
ISSUED: 2012-10-11 SHEET #: 180-9041-2 2012-05-31
Use a stud
fi
nder to locate the edges of the studs and draw a vertical line down the center of
each stud. Place enclosure assembly (
A
) on wall. Level enclosure and mark center of four
mounting holes making sure that the mounting holes are on the stud centerlines. Drill four
3/16" (5mm) dia. pilot holes to a depth of 3" (76 mm). Insert two screws (
C
), leaving a 1/2" gap
between the screw head and the wall, as shown in
fi
g. 2.1.
fi g. 2.1
Installation to Double-Stud Wall
• Installer must verify that the supporting surface will safely support the combined load of the
equipment and all attached hardware and components.
• Tighten wood screws so that wall plate is
fi
rmly attached, but do not overtighten. Overtightening
can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to
edge" stud
fi
nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into
wood studs. Installers are responsible to provide hardware for other types of mounting situations
(not evaluated by UL).
WARNING
1
C
1/2"
(13mm)
Skip to page 8 for Metal Stud Installation.
Skip to page 10 for Concrete and Cinder Block Installation.
Содержание WL-AU-AVWS