background image

6

MUTING SCREW TERMINALS (22)

Provides connection for external switch closure to activate muting functions. A switch closure from terminal 1 to 

mutes Channels 1 to 3. A switch closure from terminal 2 to   mutes Channels 2 and 3.

CH 3 OUT RCA JACK (23)

Provides a direct output of Channel 3 that is independent of EQ and muting. This output is ideal for music on hold
applications.

AUX OUT RCA JACK (24)

Provides a line level output to drive external power amps, hearing assistance systems, or as a record output for taping.
This output is after the EQ and Master Volume Control.

LOOP IN/LOOP OUT JACKS (25)

Functions as a preamp out/power amp in patch point. The Loop Out signal is a post EQ/Master Volume line level
output.

LINK SWITCH (26)

Breaks the connection between the preamp and the power amp (Loop Out/Loop In). These two jacks are shorted
together when the switch is in the "In" position. To use the Loop Out/In jacks as a patch point, the switch must be
placed in the "Out" position. The line level output signal is present at the Loop Out jack regardless of switch setting.

OUTPUTS (27)

A direct output, as well as several isolated transformer outputs, are provided to allow the proper
interface between the amplifier and the speaker system. The direct output allows direct connection to a
4 ohm speaker system. To use this output, disconnect the jumper between the 4 ohm terminal and the
XFMR terminal. Connect the speaker (or speakers) from the GND terminal to the 4 ohm terminal.

Also provided are 8 ohm, 25 volt, and 70 volt balanced outputs. To use these outputs, the jumper between 4 ohm and
XFMR must be installed. For 8 ohm speaker systems, connect between the COM terminal and the 8 ohm terminal. For
"distributed" speaker systems, 25 volt and 70 volt outputs are provided. One more output is provided on the UMA
Series amplifiers. This is a balanced, transformer-isolated line level output. This output is provided for direct connec-
tion to booster power amplifiers, etc. This output is designed to deliver 1 V RMS into a 600 ohm load. See Figures 4
through 7 for possible output connections.

NOTE: Due to the high gain and frequency response of the UMA

 

Series amplifiers, it is necessary that the input cables

be routed away from the output cables to prevent instability.

AC OUTLET (UNSWITCHED) (28)

Provides AC power for auxiliary equipment with power consumption — 300 watts maximum.

FUSE (29)

WARNING: THE FUSE SHOULD ONLY BE REPLACED WHEN THE POWER CORD HAS
BEEN DISCONNECTED FROM ITS POWER SOURCE.

CAUTION:  USING A FUSE LARGER THAN THE RECOMMENDED SIZE COULD
RESULT IN PERMANENT DAMAGE TO THE UNIT.

The fuse is located within the cap of the fuseholder. If the fuse should fail, IT MUST BE REPLACED
WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT
AND TO PREVENT VOIDING THE WARRANTY. If the unit repeatedly blows fuses, it should be
taken to a qualified service center for repair.

LINE CORD (30) (120 V products only)

For your safety, we have incorporated a three-wire line (mains) cable with proper grounding facilities. It is not advis-
able to remove the ground pin under any circumstances. If it is necessary to use the equipment without proper ground-
ing facilities, suitable grounding adaptors should be used. Less noise and greatly reduced shock hazard exist when the
unit is operated with the proper grounded receptacles.

Содержание UMA 35 T II

Страница 1: ...1 Cover for UMA 35TII ...

Страница 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Страница 3: ...tch Channel 3 output RCA phono which gives a non mutable output of Channel 3 AUX output for tape recorders etc Signal activity indicator Power indicator SPS Speaker Protection System circuitry with indicator 4 ohm 8 ohm 25 V and 70 V transformer isolated outputs 600 ohm balanced line level output AC convenience outlet Powder coated steel chassis Optional rack mounting kits available Congratulation...

Страница 4: ...es 10 dB CONTOUR SWITCH 6 The in position of this switch provides 6 dB boost at 100 Hz and 10 kHz The out position removes boost from the system MASTER 7 Controls the overall volume level of the system POWER ON LED 8 Indicates when AC power is being supplied to the unit SPS COMPRESSION ACTIVE LED 9 Illuminates when SPS circuitry is active SPS eliminates power amplifier clipping ACTIVITY SIGNAL PRE...

Страница 5: ... shown in Figure 1 CHANNEL 1 MUTE THRESHOLD 18 Adjusts the level of incoming signal from Channel 1 required to activate the muting of Channels 2 and 3 Clockwise rotation decreases the amount of signal required for muting Full counterclockwise rotation will disable muting NOTE Signal at Channel 1 input with appropriate Mute Threshold setting will mute Channels 2 and 3 CHANNELS 1 TO 3 SCREW TERMINAL...

Страница 6: ...er between 4 ohm and XFMR must be installed For 8 ohm speaker systems connect between the COM terminal and the 8 ohm terminal For distributed speaker systems 25 volt and 70 volt outputs are provided One more output is provided on the UMA Series amplifiers This is a balanced transformer isolated line level output This output is provided for direct connec tion to booster power amplifiers etc This ou...

Страница 7: ...s The Page input shall be transformer balanced 600 ohms and shall have screw terminals for the input connec tion The master section shall include one Master Volume level control two EQ controls providing 10 dB boost or cut at 100 Hz and 10 kHz and a Contour switch providing 6 dB of boost at 100 Hz and 10 kHz The unit shall have two levels of automatic muting Mute 1 shall give precedence to the Pag...

Страница 8: ...tput Loop Out AUX Out 1 V 100 ohms Inputs Channel 1 Low Z 500 µV 1 8 K ohms XLR or screw terminals High Z 50 mV 9 5 K ohms screw terminals Channel 2 Low Z 500 µV 1 8 K ohms screw terminals High Z 50 mV 9 5 K ohms RCA or screw terminals Channel 3 High Z 50 mV 9 5 K ohms RCA Page 100 mV 600 ohm transformer balanced screw terminals Loop In 1 volt 3 6 K ohms Tone Controls Bass 10 dB 100 Hz Treble 10 d...

Страница 9: ...9 Flow Diagram ...

Страница 10: ... 2 Remote Volume 10 K Lin Taper Potentiometer Shielded Cable Figure 1 GND HIGH Z LOW Z LOW Z BALANCED MIC Low Z Balanced Microphone Input Connections Figure 3 GND HIGH Z LOW Z HIGH Z INPUT High Z Input Connections Figure 2 ...

Страница 11: ...HI LO GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 1 V Balanced Output Connectors 70V Constant Voltage Distribution System Note Jumper must be in place HI LO GND 70V 25V Jumper Installed 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND Figure 5 ...

Страница 12: ...GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 4 Ω Direct Output to 4Ω Speaker Direct Output to Multiple Speakers in Parallel Total Impedance 4Ω HI LO GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 8 Ω 8 Ω Figure 7 ...

Страница 13: ...re To Ask About Products In The Following Categories Modular Series Mixer Mixer Amplifiers Rack Kits for MA Series Products Wall Mount Mixer Amplifiers Non powered Mixers Powered Mixers Equalizers Analog Equalizers Programmable Electronic Crossover Delay Processors Power Amplifiers Loudspeaker Systems Acoustical Components Utility Amplifiers Mixer Amplifiers Rack Kits for UMA Series Products Telep...

Страница 14: ...old cleaner if necessary Disconnect unit from power supply before cleaning 14 Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit...

Страница 15: ...ED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE UNDER NO CIRCUMSTANCES WILL PEAVEY BE LIABLE FOR ANY LOST PROFITS LOST SAVINGS INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THIS LIMITED WARRANTY IS THE ONLY EXPRESSED WARRANTY ON THIS PRODUCT AND NO OTHER STATE ME...

Страница 16: ...specifications subject to change without notice A Division of Peavey Electronics Corporation 711 A Street Meridian MS 39301 U S A 601 483 5376 Fax 486 1154 1995 80302222 Printed in U S A 3 96 ARCHITECTURAL ACOUSTICS TM ...

Отзывы: