background image

IEEE488.2 Common Commands

 

33 

CALCulate:NULL:OFFSet 

Syntax

 

CALCulate:NULL:OFFSet {<value>|MINimum|MAXimum} 

CALCulate:NULL:OFFSet? [MINimum|MAXimum] 

 

Description

 

Set relative value.   

 

Parameter

 

Name

 

Type 

Range 

<value> 

 

 

 

 

CALCulate:STATe 

Syntax

 

CALCulate:STATe {OFF} 

 

Description

 

Close MATH function 

 

Parameter 

Name 

Type

 

Range

 

<bool> 

 

Bool

 

{OFF}

 

 

 
 

Содержание P 4095

Страница 1: ...Digital Bench Multimeter Programming Manual P 4095 P 4096 PeakTech www peaktech de ...

Страница 2: ... of symbols 2 Parameter Type 3 Command Abbreviation 4 Contact Us 4 Third party API 4 IEEE488 2 Common Commands 6 CLS 6 IDN 6 OPC 7 RST 7 SCPI Command List 7 SENSe command subsystem 7 SENSe FUNCtion 1 2 8 SENSe VOLTage AC DC RANGe 10 SENSe VOLTage AC DC RANGe AUTO 11 SENSe VOLTage AC DC NULL 11 SENSe VOLTage DC FILTer 12 ...

Страница 3: ...e FRESistance NULL 17 SENSe FREQuency PERiod VOLTage RANGe 18 SENSe FREQuency PERiod VOLTage NULL 19 SENSe CAPacitance RANGe 19 SENSe CAPacitance RANGe AUTO 20 SENSe CAPacitance NULL 20 SENSe TEMPerature RTD TYPe 21 SENSe TEMPerature RTD NULL 22 SENSe TEMPerature RTD UNIT 22 SENSe TEMPerature RTD SHOW 23 CONFigure command sub system 23 CONFigure SCALar VOLTage AC DC 23 CONFigure SCALar CURRent AC ...

Страница 4: ...e AVERage AVERage 28 CALCulate AVERage COUNt 29 CALCulate AVERage MAXimum 29 CALCulate AVERage MINimum 30 CALCulate DB REFerence 30 CALCulate DBM REFerence 31 CALCulate FUNCtion 31 CALCulate LIMit FAIL 31 CALCulate LIMit LOWer UPPer 32 CALCulate LIMit RESet 32 CALCulate NULL OFFSet 33 CALCulate STATe 33 SYSTem command Subsystem 34 SYSTem BEEPer STATe 34 SYSTem DATE 34 SYSTem TIME 35 SYSTem VERSion...

Страница 5: ...Content iv SYSTem LOCal 36 SYSTem REMote 36 Other commands 37 AUTO 37 RANGE 37 RANGE1 38 RANGE2 39 RATE 40 MEAS 40 MEAS1 41 MEAS2 41 ...

Страница 6: ...MINimum MAXimum SENSe is the root keyword of the command VOLTage and DC are the second level and third level keywords respectively The command string starts with which separates the multiple level keywords range represents parameters available for setting represents query and the command SENSe VOLTage DC RANGe and the parameter range MINimum MAXimum are separated by space Syntax Rules SCPI languag...

Страница 7: ...OW 4 If it is not a word but a sentence then use the first letters of the former words and the whole of the last word such as Input Voltage can be IVOLtage Usage of symbols 1 Space The space is used to separate command and parameter 2 Colon If the colon is in front of the first character it means the following is Root Command When the colon is set between two keywords then it means moving from the...

Страница 8: ...lue The command required to use value type parameter It s compatible with all the common decimal display terms including optional symbol decimal point scientific notation and etc Specific value such as MIN MAX and DEF are available VOLTage AC DC RANGe range MINimum MAXimum 2 Discrete The parameter should be one of the values listed For example TEMPerature RTD UNIT C F K 3 Integer Unless otherwise ...

Страница 9: ...command must be written completely For parameters with units please refer to the detail parameter specifications in the sub system VOLTage DC RANGe Abbreviation Below VOLT DC RANG Contact Us If you have any problem or requirement when using our products please contact PeakTech Service Support Hotline 49 0 4102 42343 E mail info peaktech de Website www peaktech de Third party API The SCPI protocol ...

Страница 10: ...Introduction to the SCPI Language 5 remote control then click the SCPI command on the remoter control interface to enable SCPI protocol and communicate through SCPI protocol ...

Страница 11: ...e IDN Return the ID character string of the instrument Description The query returns the ID character string of the instrument Return Format brand model serial number X XX XX 1 2 model the model number of the instrument serial number the serial number of the instrument X XX XX the software version of the instrument 1 2 1 4095 2 4096 ...

Страница 12: ...he current operation is finished otherwise returns 0 RST Restore the instrument to its default value SCPI Command List SENSe command subsystem SenSe subsystem configuration The basic SenSe command is SENSe FUNCtion 1 2 which can choose main display and sub display measurement function FUNCtion 1 2 to switch mode Other SenSe command only change specific mode parameter don t change mode for example ...

Страница 13: ... 1 for main display 2 for sub display If leave out this parameter display defaults at 1 main display The parameter for SENSe FUNCtion 1 2 function that is can both been used as main or sub display Name Type Parameter Measure Function function discrete VOLTage AC AC voltage measure VOLTage DC DC voltage measure CURRent AC AC current measure CURRent DC DC current measure FREQuency Frequency measure ...

Страница 14: ...FRESistance Four wire Resistance measure RESistance Resistance measure TEMPerature RTD Temperature measure The parameter for SENSe FUNCtion 2 function that is can only been used as sub display Name Type Parameter Measure Function function discrete NONe close sub display Return format Use quotation to keep abbreviated selected return function no available keyword Return value Measure function VOLT ...

Страница 15: ...iode test FRES Four wire Resistance measure RES Resistance measure TEMP Temperature measure For FUNCtion2 command if not start dual display then return NONe SENSe VOLTage AC DC RANGe Syntax SENSe VOLTage AC DC RANGe range MINimum MAXimum SENSe VOLTage AC DC RANGe MINimum MAXimum Description Select valid measuring range for AC or DC voltage measure Parameter Name Type Range ...

Страница 16: ...600mV 6 6V 60 60V 600 600V 1000 1000V Return format Return query result by scientific notation SENSe VOLTage AC DC RANGe AUTO Syntax SENSe VOLTage AC DC RANGe AUTO OFF ON SENSe VOLTage AC DC RANGe AUTO Description Close or start auto scale for AC or DC voltage measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query SENSe VOLTage AC DC NULL S...

Страница 17: ...pe Range Default bool Bool OFF ON OFF Return format Return 0 OFF or 1 ON after query SENSe VOLTage DC FILTer Syntax SENSe VOLTage DC FILTer STATe OFF ON SENSe VOLTage DC FILTer STATe Description Close or start simulated filter for DC measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query ...

Страница 18: ...ter Name Type Range Default bool bool OFF ON OFF Note OFF for all the measuring range DC voltage input impedance is fixed at 10 MΩ ON DC voltage measurement input impedance changes in accordance with measuring range Input impedance is 10 GΩ at 200mV and 2V measuring range 10 MΩ at 20V 200V and 1000V measuring range Return format Return 0 OFF or 1 ON after query SENSe CONT THREshold Syntax SENSe CO...

Страница 19: ... MAXimum Description Select fixed measuring range for AC DC current measurement Parameter Name Type Range range discrete 4096 AC 20E 3 20mA 200E 3 200mA 2 2A 10 10A DC 200E 6 200uA 2E 3 2mA 20E 3 20mA 200E 3 200mA 2 2A 10 10A 4095 AC 60E 3 60mA 600E 3 600mA 6 6A 10 10A DC 600E 6 600uA 6E 3 6mA 60E 3 60mA 600E 3 600mA 6 6A 10 10A Return format Return query result by scientific notation ...

Страница 20: ...art auto scale adjustment for AC DC current measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query SENSe CURRent AC DC NULL Syntax SENSe CURRent AC DC NULL OFF ON Description Close or start relative value for AC DC current measurement Parameter Name Type Range Default bool Bool OFF ON OFF Return format ...

Страница 21: ... simulated filter for DC current measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query SENSe RESistance FRESistance RANGe Syntax SENSe RESistance FRESistance RANGe range MINimum MAXimum SENSe RESistance FRESistance RANGe MINimum MAXimum Description Select fixed measuring range for RESistance or FRESistance Parameter Name Type Range ...

Страница 22: ...ult by scientific notation SENSe RESistance FRESistance RANGe AUTO Syntax SENSe RESistance FRESistance RANGe AUTO OFF ON SENSe RESistance FRESistance RANGe AUTO Description Close or start auto scale adjustment for resistance measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query SENSe RESistance FRESistance NULL Syntax SENSe RESistance FRES...

Страница 23: ...uency PERiod VOLTage RANGe Syntax SENSe FREQuency PERiod VOLTage RANGe range MINimum MAXimum SENSe FREQuency PERiod VOLTage RANGe MINimum MAXimum Description Select fixed voltage measuring range for FREQuency or PERiod Parameter Name Type Range range Discrete 4096 200E 3 200mV 2 2V 20 20V 200 200V 750 750V 4095 600E 3 600mV 6 6V 60 60V 600 600V 750 750V Return format Return query result by scienti...

Страница 24: ...rement Parameter Name Type Range Default bool Bool OFF ON OFF Return format Return 0 OFF or 1 ON after query SENSe CAPacitance RANGe Syntax SENSe CAPacitance RANGe range MINimum MAXimum SENSe CAPacitance RANGe MINimum MAXimum Description Select fixed measuring range for capacitance measurement Parameter Name Type Range range Discrete 2E 9 2nF 20E 9 20nF 200E 9 200nF 2E 6 2uF 20E 6 20uF ...

Страница 25: ...tance RANGe AUTO OFF ON SENSe CAPacitance RANGe AUTO Description Close or start auto scale adjustment for capacitance measurement Parameter Name Type Range Default bool Bool OFF ON ON Return format Return 0 OFF or 1 ON after query SENSe CAPacitance NULL Syntax SENSe CAPacitance NULL OFF ON Description Close or start relative value for capacitance measurement ...

Страница 26: ...NSe TEMPerature RTD TYPe Syntax SENSe TEMPerature RTD TYPe RTD Type SENSe TEMPerature RTD TYPe Description Select RTD type for temperature measurement Parameter Name Type Range RTD Type Discrete KITS90 NITS90 EITS90 JITS90 TITS90 SITS90 RITS90 BITS90 W5_26 W3_25 PT100 PT10 Cu100 Cu50 Return format Return the query result by character ...

Страница 27: ...erature measurement Parameter Name Type Range Default bool Bool OFF ON OFF Return format Return 0 OFF or 1 ON after query SENSe TEMPerature RTD UNIT Syntax SENSe TEMPerature RTD UNIT C F K Description Select temperature unit for temperature measurement optional for C Celsius F Fahrenheit K Kelvin Return format Return the query result by character ...

Страница 28: ...both temperature and measured value Return format Return the query result by character CONFigure command sub system CONFigure sub system is used to switch measure mode CONFigure SCALar VOLTage AC DC Syntax CONFigure SCALar VOLTage AC DC range MINimum MAXimum DEF AUTO Description Restore all the measurement and trigger parameters to default process AC DC voltage measurement Then set the measuring r...

Страница 29: ...UTO Description Restore all the measurement and trigger parameters to default process AC DC current measurement Then set the measuring range Parameter Name Type Range range Discret e 4096 AC 20E 3 20mA 200E 3 200mA 2 2A 10 10A DC 200E 6 200uA 2E 3 2mA 20E 3 20mA 200E 3 200mA 2 2A 10 10A 4095 AC 60E 3 60mA 600E 3 600mA 6 6A 10 10A DC 600E 6 600uA 6E 3 6mA 60E 3 60mA 600E 3 600mA 6 6A 10 10A CONFigu...

Страница 30: ...Ω 100E6 100MΩ 4095 600 600Ω 6E3 6KΩ 60E3 60KΩ 600E3 600KΩ 6E6 6MΩ 60E6 60MΩ 100E6 100MΩ CONFigure SCALar FREQuency PERiod Syntax CONFigure SCALar FREQuency PERiod range MINimum MAXimum DEF AUTO Description Restore all the measurement and trigger parameters to default process FREQuency PERiod measurement Then set the measuring range Parameter Name Type Range range Discrete 4096 200E 3 200mV 2 2V 20...

Страница 31: ...ter Name Type Range range Discret e 2E 9 2nF 20E 9 20nF 200E 9 200nF 2E 6 2uF 20E 6 20uF 200E 6 200uF 10E 3 10mF CONFigure SCALar TEMPerature RTD Syntax CONFigure SCALar TEMPerature RTD RTD Type Description Restore all the measurement and trigger parameters to default process temperature measurement Then set the RTD type Parameter Name Type Range RTD Type Discret e KITS90 NITS90 EITS90 JITS90 TITS...

Страница 32: ...ent Parameter CONFigure SCALar CONTinuity Syntax CONFigure SCALar CONTinuity Description Restore all the measurement and trigger parameters to default process continuity test Parameter CALCulate command Subsystem CALCulate command is used to manage math function Sum up limit db dbm relative value Function command is used to switch math mode from four modes AVERage DB DBM LIMit ...

Страница 33: ...Culate AVERage ALL Description Query returns the minimum value maximum value average value and count of all measurements taken since the statistics were last cleared Parameter none CALCulate AVERage AVERage Syntax CALCulate AVERage AVERage Description Query returns the average value of all measurements taken since the statistics were last cleared Parameter none ...

Страница 34: ...iption Query returns the number of measurements taken since the statistics were last cleared Parameter none CALCulate AVERage MAXimum Syntax CALCulate AVERage MAXimum Description Query returns the maximum value of all measurements taken since the statistics were last cleared Parameter none ...

Страница 35: ...lue of all measurements taken since the statistics were last cleared Parameter none CALCulate DB REFerence Syntax CALCulate DB REFerence Ref R MINimum MAXimum CALCulate DB REFerence Description Set DB relative resistance Parameter Name Type Range Ref R Discret e 50 75 93 110 124 125 135 150 250 300 500 600 800 900 1000 1200 8000 ...

Страница 36: ...e Parameter Name Type Range Ref R Discret e 50 75 93 110 124 125 135 150 250 300 500 600 800 900 1000 1200 8000 CALCulate FUNCtion Syntax CALCulate FUNCtion NULL DB DBM AVERage LIMIt CALCulate FUNCtion Description Set mathematic calculation as NULL DB DBM AVERage or LIMIt CALCulate LIMit FAIL Syntax CALCulate LIMit FAIL Description Query returns the limit test results ...

Страница 37: ...ALCulate LIMit LOWer UPPer value MINimum MAXimum CALCulate LIMit LOWer UPPer Description Set lower or upper line for limit value Parameter Name Type Range value CALCulate LIMit RESet Syntax CALCulate LIMit RESet Description Clears the flag bit and count of limit test Parameter none ...

Страница 38: ...CALCulate NULL OFFSet value MINimum MAXimum CALCulate NULL OFFSet MINimum MAXimum Description Set relative value Parameter Name Type Range value CALCulate STATe Syntax CALCulate STATe OFF Description Close MATH function Parameter Name Type Range bool Bool OFF ...

Страница 39: ...Per STATe ON OFF SYSTem BEEPer STATe Description Start or close the buzzer Parameter Name Type Range 默认值 bool Bool ON OFF ON Return format Return 0 OFF or 1 ON after query SYSTem DATE Syntax SYSTem DATE Description Query date includes year month and day inside device real time clock Parameter ...

Страница 40: ... query result SYSTem TIME Syntax SYSTem TIME Description Query time includes hour minute and second inside device real time clock Parameter Return format Return query result SYSTem VERSion Syntax SYSTem VERSion Description Query SCPI version Parameter ...

Страница 41: ...EE488 2 Common Commands 36 Return format Return query result SYSTem LOCal Syntax SYSTem LOCal Description Exit SCPI mode Parameter SYSTem REMote Syntax SYSTem REMote Description Enter SCPI mode Parameter ...

Страница 42: ...on Enable autoscale Parameter Return format Return autoscale setting 1 for auto 0 for manual RANGE Syntax RANGE range1 DEF Description Set measuring range Parameter Name Type Range range1 Discre DCV 4096 1 200mV 2 2V 3 20V 4 200V 5 1000V 4095 1 600mV 2 6V 3 60V 4 600V 5 1000V ...

Страница 43: ... 1 600mV 2 6V 3 60V 4 600V 5 750V TEMP 1 KITS90 2 NITS90 3 EITS90 4 JITS90 5 TITS90 6 SITS90 7 RI TS90 8 BITS90 9 W5_26 10 W3_25 11 P T100 12 PT10 13 Cu100 14 Cu50 RANGE1 Syntax RANGE1 Description Query main display measuring range Parameter Return format DCV 4096 1 200mV 2 2V 3 20V 4 200V 5 1000V 4095 1 600mV 2 6V 3 60V 4 600V 5 1000V ACV 4096 1 200mV 2 2V 3 20V 4 200V 5 750V 4095 1 600mV 2 6V 3 ...

Страница 44: ... Description Query sub display measuring range Parameter Return format DCV 4096 1 200mV 2 2V 3 20V 4 200V 5 1000V 4095 1 600mV 2 6V 3 60V 4 600V 5 1000V ACV 4096 1 200mV 2 2V 3 20V 4 200V 5 750V 4095 1 600mV 2 6V 3 60V 4 600V 5 750V DCI 4096 1 200uA 2 2mA 3 20mA 4 200mA 5 2A 6 10A 4095 1 600uA 2 6mA 3 60mA 4 600mA 5 6A 6 10A ACI 4096 1 20mA 2 200mA 3 2A 4 10A 4095 1 60mA 2 600mA 3 6A 4 10A FREQ PE...

Страница 45: ...ange speed Discret e F high speed M middle speed L low speed Return format Return current speed F for high speed M for middle speed L for low speed MEAS Syntax MEAS Description If start dual display return main and sub display measured value or return main display measure value Parameter Return format ...

Страница 46: ...splay the return format is main display measured value sub display measured value MEAS1 Syntax MEAS1 Description Return main display measured value Parameter Return format Return measured result by scientific notation MEAS2 Syntax MEAS2 Description Return sub display measured value Parameter ...

Страница 47: ...IEEE488 2 Common Commands 42 Return format Return measured result by scientific notation ...

Отзывы: