4.4.3. Timer Range
Timer range setting denotes that you can set the last number of timer parameter group and output mode. You can find out
the TimerRng submenu of system menu only in timer status. If turn on the timing output, the system will output the pre-set
parameters between 0 and the set number at sequence or loop mode.
(1) In timer status:
Normal
– Mode
Press the System
key, enter [System → CH1 (CH2) →TimerRng].
Parallel, Series Mode
Press the System
key, enter [System → TimerRng].
Plus-minus Mode
Press the System
key, enter [System → Positive →TimerRng].
The timer range setting box pops up. Use the numeric keys enter a number (0~99), press the
▲ / ▼ key to
switch between Sequence and Loop, press the
key to confirm.
4.4.4. Turn On/Off Timing Output
In timer status:
Normal - Mode
Press orange ON/OFF key to turn on/off the timing output of Channel 1.
Press blue ON/OFF key to turn on/off the timing output of Channel 2.
Parallel, Series or Plus-minus Mode
Press orange ON/OFF key to turn on/off the timing output.
Note:
In the process of timing output, closing the channel output will reset the timer; turning on the channel again will restart t he
timing output and the timer.
4.5. Save/Recall/Record
The PeakTech 6180 supports operations with a USB flash device and local file storage, including: store, recall and delete
current setting parameters. The current data of the channel can be recorded into a txt file, which stored in USB disk. You
can connect the USB disk to the
①
USB Host interface in Figure 3-8. After connecting the USB disk successfully, an icon
will be shown at the top of the screen.
4.5.1. Save System Parameter
In Normal Status, press the Save key to save the parameters about current working mode and the output voltage/current,
the O.V.P/O.C.P of current mode. You can name the setting files. This function is not available in Timer Status.
(1) In Normal Status, press the Save key to enter the function interface (press it again to exit). Press the
▲ / ▼ key
to choose the storage location as "Local" or "UDisk". Turn the knob to change the selected character in "Save
name" input box. Press the
>
key to add the next character. Press the
<
key to select the previous character.
Press the
← key to delete the selected character.
(2) Press the
key to store after editing the file name.
-47-