![PeakTech 4090 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/peaktech/4090/4090_operation-manual_1517609026.webp)
3.3. DC Voltage
Range
Resolution
Accuracy
220 mV
0,01 mV
± (0,05% + 6 dgt.)
2,2 V
0,1 mV
22 V
1 mV
220 V
10 mV
600 V
0,1 V
Input Impedance:
Range 220mV: > 1000M
other Ranges: 10M
The above accuracies are specified from 0% to 100% of range.
3.4. AC Current
Range
Resolution
Accuracy
40 Hz ~ 100 Hz
100 Hz ~ 1 kHz
1 kHz ~ 5 kHz
220 µA
0,01 µA
± (0,8% + 30 dgt.) ± (1% + 30 dgt.) ± (1,2% + 30 dgt.)
2200 µA
0,1 µA
± (0,8% + 30 dgt.) ± (1% + 30 dgt.) ± (1,2% + 30 dgt.)
22 mA
1 µA
± (0,8% + 30 dgt.) ± (1% + 30 dgt.) ± (1,2% + 30 dgt.)
220 mA
10 µ
± (0,8% + 30 dgt.) ± (1% + 30 dgt.) ± (1,2% + 30 dgt.)
10 A
10 mA
± (1,0% + 30 dgt.) ± (1,5% + 30 dgt.) ± (2,0% + 30 dgt.)
Max. Allowable Input Current: 10A
( For measurements > 2A: measurement duration <10 seconds, and interval >15 minutes )
All AC current ranges are specified from 10% to 100% of range except the 10A range, which is
specified from 20% to 100% of range.
3.5. DC Current
Range
Resolution
Accuracy
220 µA
0,01 µA
± (0,2% + 15 dgt.)
2200 µA
0,1 µA
22 mA
1 µA
220 mA
10 µA
10 A
1 mA
± (0,8% + 1 dgt.)
Max. Allowable Input Current: 10A
( For measurements > 2A: measurement duration <10 seconds, and interval >15 minutes )
All AC current ranges are specified from 10% to 100% of range except the 10A range, which is
specified from 20% to 100% of range.
-25-