64-
Exceed Voltage!!!
Over Hot!!!
6.8.1 Over-voltage Protection
If the set voltage limit was exceeded, the Load deactivates the input with a warning tone. Following will
be shown on the LCD:
6.8.2 Over-current Protection
If the set current limit was exceeded, "OC" will be shown on the LCD and a warning tone will be heard. If
the current will not be decreased soon and reaches 110 % of the set max. value, the Load input will be
deactivated automatically.
6.8.3 Overload Protection
If the set power limit was exceeded, "OP" will be shown on the LCD and a warning tone will be heard. If
the power will not be decreased soon and reaches 110 % of the set max. value, the Load input will be
deactivated automatically.
6.8.4 Reverse Polarity Protection
Warning: During the reverse-polarity condition, current limiting functionality of the Load is not
active!
The Load deactivates the input as soon as a reverse-polarity condition was detected. Following
message will be seen on the LCD:
6.8.5 Thermal Protection
Should the temperature inside the instrument exceed 80 °C, a warning tone will be heard and the input
of the Load will be turned off. Following message will be seen on the LCD:
Reverse Voltage!!!
Содержание 2275