60-
6.4 Const. Resistance Mode (CR Mode)
In CR Mode, the Load will set the resistance to a desired value. The current will therefore go up or down
together with the applied voltage.
Being in any other mode, press
【
R-SET
】
to enter the CR Mode. Press then
【
ON/OFF
】
to activate
the Load.
If the Load is deactivated, you can change the desired current with the rotating knob. Press
【
R-SET
】
once again to enter the value per key field.
The range of both DC Loads is 0.1
Ω to 4 kΩ.
6.5 Battery Test Mode
The battery test mode works as follows: Constant current will be drawn from the battery. That eventually
will cause the voltage to drop to a pre-set cut-off value. The time needed for the voltage to drop to that
value and the drawn current allow the calculation of battery capacity.
Immediately after the battery test was completed, discharge time and battery capacity in Ah will be
displayed. If not, press
【
ENT
】
.