- 72 -
The pass/Fail function:
Menu
Settings
Description
Operate
Start
Stop
Start operation
Stop operation
Output
Pass
Fail
Beep
Stop
Info
Signal tested corresponds with the rule
Signal tested not correspond with the rule
Beep when it satisfies the rule
Stop once satisfying the rule
Control the display status of info frame
Rule
Source
Horizontal
Vertical
Create
Select the source as CH1, CH2, CH3 or CH4
Change the Horizontal tolerance value by clicking
or
Change the Vertical tolerance value by clicking
or
Use the rule set as testing rule
Save rule
Number
Save
Load
Select any one from Rule1 - Rule8 as your rule name
Select
Save
to save the rule
Load some rule as the testing rule
Pass/Fail test:
Detect whether the input signal is within the limits of the rule, if it exceeds limits of the rule, it is "Fail";
otherwise it is "Pass". Also, it can output fail or pass signal by built-in and configurable output port.
To run the test, read the following steps:
1. Click
to call up the menu panel. Click the
P/F s
oftkey on panel to switch to the ON state.
2.
Create rule
: Select
Rule
in the bottom menu. Select
Source
in the right menu. Set
Horizontal
tolerance and
Vertical
tolerance in the right menu. Select
Create
in the right menu to create the
rule.
3.
Set output type
: Select
Output
in the bottom menu to enter output option setting. Choose any
one or two of the options "
Pass
", "
Fail
" or "
Beep
". "
Pass
" and "
Fail
" are mutually exclusive
options, which could not be chosen simultaneously. "
Stop
" means stop once the condition
satisfies your setting.
4.
Begin to test:
Select
Operate
in the bottom menu, switch it to
Start
, the test will begin.
5.
Save rule:
Select
SaveRule
in the bottom menu. Select the save location in the left menu, and
then select
Save
in the right menu to save the rules, which could be called up at once when
need. Select
Load
to call up the rule saved.
Note:
1.
When Pass/Fail is ON, if XY or FFT is ready to run, then Pass/Fail will be closed; under the
mode of XY or FFT, Pass/Fail is unable.
2.
Under the mode of Factory, Auto Scale and Auto Set, Pass/Fail will be closed.
3.
When no save setting left in the rule save, tip will be given to show "NO RULE SAVED".
4.
Under the status of stop, data comparing will stop, and when it goes on running, the number of
Pass/Fail will increase from the former number, not from zero.
5.
When the waveform playback mode is on, Pass/Fail is used to test the played-back waveform
specially.