- 25 -
6.1 Set the vertical system
The VERTICAL functions include 2 menu buttons such as CH1
~
CH2 (2CH models) and CH1
~
CH 4 (4 CH Models) as well as 2 rotary controls for vertical and horizontal setting, to be set for
each measuring channel.
Settings CH1
~
CH2, CH1
~
CH4
Each channel has an independent vertical menu with functions based on this channel.
Activate / deactivate waveform display
Pressing the CH1
~
CH2, CH1
~
CH4 buttons has the following effect:
• If the waveform is switched off, it is switched on and the channel menu is displayed.
• If the waveform is already switched on, the channel menu is also displayed.
• If the waveform is already switched on and the channel menu is displayed, switch the waveform
and the channel menu off again with this action
Function
menu
Settings
Description
Coupling
DC
AC
GROUND
Pass both AC and DC components of the input
signal.
Blocks the DC component in the input signal
Disconnect the input signal.
Inverted
On
Off
Display inverted waveform
Display original waveform
Probe
Attenuation
0.001X
to
1000X
Select a attenuation factor that corresponds to
the probe in order to obtain a correct
representation of the vertical scale factor.
Current
measure -
ment
Yes
No
If you are measuring current by probing the
voltage drop across a resistor, choose Yes
A/V (mA/V)
V/A (mV/A)
Click
or
to set the Amps/Volts ratio. The
range is 100 mA/V - 1 KA/V
Amps/Volts ratio = 1/Resistor value
Volts/Amp ratio is automatically calculated
Limit
Full band
20M
Full bandwidth
Limits the channel bandwidth to 20 MHz to
reduce visible noise