Probe
1X position
10X position
Bandwidth
Up to 4 MHz (DC)
Up to full bandwidth (DC)
Attenuation rate
1:1
10:1
Compensation range
10pf
~
35pf
Input resistance
1M
Ω
+/-2
%
10M
Ω
+/-2
%
Input impendence
85pf
~
115pf
14.5pf
~
17.5pf
Input voltage
150 V DC
300 V DC
8.2.1. Meter
Voltage (VDC)
Input Impedance: 10M
Ω
.
Max. Input Voltage: 1000V (DC or AC peak-to-peak value)
Range
Accuracy
Resolution
400 mV
+/- 1.5% +/-2 digit
100 µV
4 V
+/- 1% +/-1 digit
1 mV
40 V
10 mV
400 V
100 mV
Voltage (VAC)
Input Impedance: 10M
Ω
Max. Input Voltage: 750V (AC, virtual value)
Frequency range: from 40Hz to 400Hz.
Display: Virtual value of the sine wave
Range
Accuracy
Resolution
4 V
+/- 1.0% +/-3 digits
1 mV
40 V
10 mV
400 V
100 mV
750 V
+/- 1.5% +/-3 digits
1 V
Direct Current (DC)
Range
Accuracy
Resolution
40 mA
+/- 1.5% +/- 1 digit
10 µA
400 mA
+/- 1.5% +/- 1 digit
100 µA
10 A
+/- 3% +/- 3 digit
10 mA
Alternating Current (AC)
Range
Accuracy
Resolution
40 mA
+/- 1.5% +/- 3 digit
10 µA
400 mA
+/- 2% +/- 1 digit
100 µA
10 A
+/- 5% +/- 3 digit
10 mA
-118-