Figure 51: Autoscale Horizontal- Vertical multi-period waveforms
Note:
1. Entering into Autoscale function and flicker will be on the top left corner. (flicker every 0.5 second)
2. At the mode of Autoscale, the oscilloscope can self-estimate “Trigger mode” (Edge, Video, and Alternate)
and “Type” (Edge, Video). If now, you press “Trigger mode” or “Type”, the forbidden information will
display on the screen.
3. At the mode of XY and STOP status, pressing
AUTO SET
to enter into Autoscale, Oscilloscope switches
to YT mode and AUTO status.
4. At the mode of Autoscale, Oscilloscope is always in the state of DC coupling and AUTO triggering. In this
case, the forbidden information will be showing when making Triggering or Coupling settings.
5. At the mode of Autoscale, if adjust the vertical position, voltage division, trigger level or time scale of CH1
or CH2, the oscilloscope will turn off Autoscale function and if press AUTOSET again, the oscilloscope will
enter into Autoscale.
6. Turn off the submenu at the Autoscale menu, the Autoscale is off and turn on the submenu still enters into
the function.
7. When video triggering, the horizontal time scale is 50µs. If one channel is showing edge signal, the other
channel is showing video one, the time scale refers to 50µs as video one as standard.
8. While the Autoscale is working, below settings will be made forcibly.
9. The unit will switch from non-main time base to main time base status.
10. The unit will switch to Peak detection menu while in the state of Average sampling mode.
7.12. Record (only P 1195)
Waveform record: The function provides you to set the time interval between the frames and record the
waveform up to 3000 numbers and get the better analysis effect more than before through Playback and Save
functions.
Four record modes: Record, Playback, Save, Off.
Record:
Record the waveforms up till the set number of frames at specified time intervals.
-106-