Operation
5.1
Turning On the PCAN-Router Pro
After applying a supply voltage, the PCAN-Router Pro does a reset
and is turned off (power-down mode, Power LED off). For turning
on the PCAN-Router Pro needs a wake-up signal.
The standard equipment of the PCAN-Router Pro provides High-
speed CAN transceiver modules with wake-up function that auto-
matically initialize a wake-up when a supply voltage is applied.
Therefore, the PCAN-Router Pro immediately turns on by itself
(Power LED on).
Transceiver Module
Transmission Standard
Wake-up
Function
PCAN-Transceiver TJA1041
Transceiver installed by default.
High-speed CAN ISO 11898-2
yes
PCAN-Transceiver PCA82C251
High-speed CAN ISO 11898-2
no
PCAN-Transceiver MAX3057-ISO High-speed CAN ISO 11898-2
no
PCAN-Transceiver TH8056
Single-wire CAN SAE J2411
yes
PCAN-Transceiver TJA1055
Low-speed CAN ISO 11898-3
yes
Note:
Having customized equipment, if there is no CAN tran-
sceiver module with wake-up function, the PCAN-Router Pro
must be switched on with an external wake-up signal (see
section 5.7.3 on page 37).
5.2
Default Bit Rates of the CAN Channels
In order to ensure the communication with the PCAN-Router Pro,
default bit rates are preset for CAN channels according to the used
CAN transceiver module.