Background Information 
 

Cat  5  (short  for  Category  5)  network  cables  are  typically  used  for  10  Base-T 
Networks  and  100  Base-T  Networks  operating  at  10Mbps  and  100Mbps 
respectively.  Many  new  networks  are  now  being  specified  to  operate  at  even 
higher  data  rates,  these  are  sometimes  referred  to  as  Cat  5e  (e  for  enhanced) 
and Cat 6 networks. 
 
The cables themselves usually consist of 4 twisted pairs, a total of 8 lines. The 
actual connection pattern from one end of the cable to the other end depends on 
the  network  type  and  also  the  equipment  type.  Often,  only  2  twisted  pairs  (4 
wires) are actually used for data communication for many networks, however, 
for universal compatibility all 8 connections are normally wired. 
 

Straight-Through Patch Cables 

The  simplest  network  cables  are 
simply  called 

Patch  Cables

  or 

Straight-Through  Cables

.  These  are 

normally  wired  with  each  of  the  8 
wires 

connected 

to 

the 

same 

corresponding  contact  at  each  end  of 
the cable, 1 to 1, 2 to 2 and so on. 
 

 
These  are  generally  used  for 
connecting 

computers 

to 

hubs (routers or switches) or 
simply  between  a  PC  and  a 
wall 

socket 

(which 

eventually  connects  to  a 
hub). 
 
 

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1. Orange/White
2. Orange
3. Green/White
4. Blue
5. Blue/White
6. Green
7. Brown/White
8. Brown

PC

PC

Server

Hub/Router

Straight-Through 

Patch Cable

Straight-Through 

Patch Cable

Straight-Through 

Patch Cable

Printer

Typical Use for Straight-Through Patch Cables

Straight-Through 

Patch Cable

Содержание Atlas IT

Страница 1: ...ble Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001 2013 In the interests of development information in this guide is subject to chan...

Страница 2: ...damage the instrument socket and the terminator socket permanently leading to intermittent faulty readings that you can t rely on We are unable to provide warranty cover for misuse by using connectors...

Страница 3: ...ntroduction 3 Important Notice 4 Background Information 5 Straight Through Cables Crossover Cables Other Cable Configurations Using Your Atlas IT 7 Analysis Results 9 Good Cables 9 Faulty Cables 14 Op...

Страница 4: ...lines Displays the full connection pattern of the cable being analysed Compatible with optional Identified Terminators allowing multiple cable runs to be uniquely identified and analysed Supplied with...

Страница 5: ...pment under test damage to the Atlas IT and invalidation of the manufacturer s warranty Additionally the absolute voltage limit of 80V between any pair of wires is stated for a maximum duration of 15...

Страница 6: ...on for many networks however for universal compatibility all 8 connections are normally wired Straight Through Patch Cables The simplest network cables are simply called Patch Cables or Straight Throu...

Страница 7: ...re actually a number of wiring configurations that can be used to produce a crossover cable The cable connection pattern shown above is the most common However the Atlas IT will recognise all variatio...

Страница 8: ...wo short patch cables to allow for the testing of network cabling that is accessible only by sockets or a patch panel This is illustrated here Ideally the total cable length should not exceed 150 metr...

Страница 9: ...ator and the local end has been connected to the Atlas IT instrument you are ready to perform a test Simply press the on test button The Atlas IT will first perform a short search procedure to determi...

Страница 10: ...croll off when you re ready The next information to be displayed is the confirmation of the full connection pattern between the terminator Term and the Atlas IT Atlas As can be seen from the display h...

Страница 11: ...Atlas IT User Guide July 2013 Rev 7 Page 10 This page is intentionally blank...

Страница 12: ...Atlas IT User Guide July 2013 Rev 7 Page 11...

Страница 13: ...Atlas IT User Guide July 2013 Rev 7 Page 12...

Страница 14: ...Atlas IT User Guide July 2013 Rev 7 Page 13 This page is intentionally blank...

Страница 15: ...ction s In this example the closest cable type match is an 8 wire crossover cable Pressing the scroll off button to view the next pages reveals the nature of the fault Here a flashing cross symbol ind...

Страница 16: ...as the standard non identified terminators They are automatically recognised by the Atlas IT and the identity number is displayed along with the cable analysis results Up to 24 Identified Terminators...

Страница 17: ...to serve as a reminder of course please seek guidance from a qualified person if you are unsure how to implement this information First the unit confirms the connection patterns for the two most comm...

Страница 18: ...unction or leak damage The unit may continue to operate following a low battery warning performance however may be adversely affected To replace the battery unscrew the three screws to remove the rear...

Страница 19: ...hat offer ease of use and durability RJ45 Breakout Adapter A unique adapter has been designed to enhance your Atlas IT for the analysis of un terminated cabling This is a professional assembly complet...

Страница 20: ...r Dimensions 18 x 15 x 14 mm Notes 1 Dependant on quality of cable connections and influence of external interference 2 Specified for durations no longer than 60 seconds 3 Specified for durations no l...

Страница 21: ...connected between the Atlas IT and the Terminator This will be displayed if the cable being analysed is not similar to any of the types stored in the Atlas IT The connection pattern will still be dis...

Страница 22: ...ate of purchase This warranty covers the cost of repair or replacement due to defects in materials and or manufacturing faults The warranty does not cover malfunction or defects caused by a Operation...

Страница 23: ...ndividual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic pro...

Отзывы: