Safety Notices

Peak Scientific Instruments cannot anticipate every possible circumstance which may 

represent a potential hazard. The warnings detailed within this document detail the 

most known potential hazards, but by definition cannot be all inclusive. If the user 

employs an operating procedure, item of equipment or a method of working which 

is not specifically recommended by Peak Scientific, the user must ensure that the 

equipment will not be damaged or become hazardous to persons or property.

Symbols

This document uses the following symbols to highlight specific areas important to the 

safe and proper use of the Generator

A WARNING notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

personal injury or in the worst case death. Do not proceed beyond a WARNING 

notice until the indicated conditions are fully understood or met.

A CAUTION notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

damage to the Generator or the Application. Do not proceed beyond a CAUTION 

notice until the indicated conditions are fully understood or met. 

Caution, risk of electric shock. Ensure power to the Generator has been removed 

before proceeding.

Safety Notice to Users

These instructions must be read thoroughly and understood before 

installation and operation of your Peak Generator. Use of the generator 

in a manner not specified by Peak Scientific MAY impair the SAFETY 

provided by the equipment. 

When handling, operating or carrying out any maintenance, personnel 

must employ safe engineering practices and observe all relevant local 

health and safety requirements and regulations. The attention of UK 

users is drawn to the Health and Safety at Work Act 1974, and the 

Institute of Electrical Engineers regulations.

If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired.

‘The MS Bench SCI 1 & SCI 2 are designed to support most RUO SCIEX 

MS Systems (except TripleTOF 5600+, 6600, and 6600+) per the 

weights and dimensions provided in Sciex site prep manuals.

The G SCI 1 & G SCI 2 are designed to support Sciex liquid 

chromatography (LC) systems.

WARNING

WARNING

WARNING

WARNING

CAUTION

Page 3

WARNING

WARNING

Содержание MS Bench

Страница 1: ...MS Bench All Models Installation Guide Rev 5 RSID 3024 IG 0028 EN 24 08 20 MS Bench All Models Installation Guide...

Страница 2: ...acilitate safe and correct installation and initial configuration of your Peak Scientific gas generator For more extensive user operation directions we recommend you download the User Manual from the...

Страница 3: ...ed to could cause damage to the Generator or the Application Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met Caution risk of electric shock Ensure pow...

Страница 4: ...19 04 1026 1 4 Teflon Tubing 00 1266 2x3m Fittings Kit x2 1 4 Compression Fitting 02 4421 x1 1 4 6mm Push Fit Fitting 02 4600 x3 Flow Control SIlencer 02 1096 MS Bench G SCI 1 G SCI 2 Only MS Bench SC...

Страница 5: ...ack the generator from the shipping crate and position on a flat surface in desired area 1 2 To extend the levelling feet first pull the ratchet handle out There is a ring pull on the handle to aid re...

Страница 6: ...on the end of the tab Pressing this will reverse the direction of the ratchet mechanism ratcheting to the left will then raise the foot from the floor 4 With the foot in position push the tab back in...

Страница 7: ...trol Silencer 02 1096 fittings to the Curtain Source Exhaust Ports 02 4600 02 4600 02 1096 02 1096 There are Transit Bolts located on the underside of the generator The G SCI 1 has 2 bolts and the G S...

Страница 8: ...the cable into the mains input at the rear of the generator Connect the 6mm PE Tubing 00 1282 to the 6mm Push Fit Fitting 02 4600 Fit the other end of the tubing to a suitable drain connection or con...

Страница 9: ...10 MS Bench G SCI 1 G SCI 2 100 240v 10 MS Bench SCI 1 SCI 2 single phase power supply CAUTION ensure the correct cable has been selected for your electrical supply UK EU US 230V CAUTION Switch the ge...

Страница 10: ...el and check gauges have risen to the factory set pressures stated in the User Manual The gauges are located in the bottom left hand corner of the G SCI 1 For G SCI 2 models the gauges are located beh...

Страница 11: ...Page 11 14 13 Switch the generator power OFF using the switch on the front panel The purge is now completed and the silencer fittings can be removed from the Curtain Source Exhaust ports...

Страница 12: ...o the fittings attached to the SOURCE EXHAUST Connect the other end of the tubing to the corresponding gas inlets of your instrument 00 1266 00 1266 Select the 5 16 Compression Fitting 3303538 1 4 Com...

Страница 13: ...Page 13 18 17 CONGRATULATIONS Your Peak Scientific MS Bench is now fully installed and operational Switch the generator power ON using the switch on the rear panel...

Страница 14: ...erator is to be installed further away from the instrument then attention needs to be paid to pressure drops that could occur The maximum distance away from the instrument the generator can be placed...

Страница 15: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 16: ...All Models Installation Guide Rev 5 RSID 3024 IG 0028 EN 24 08 20 Peak Scientific has highly trained fully certified Field Service Engineers located in over 20 countries across every continent around...

Отзывы: