Page 22
Service Indication Reset
Once the service has been completed the Service Indication LED can be reset in the
main control PLC. This will be performed by the Peak Service Engineer or trained
service representative that completes the service operation.
High Duty Indication
The Genius 3045 has a ‘HIGH DUTY’ indicator on the front panel. This indicator
monitors the running condition of the internal compressors and illuminates when they
have been operating continually for a period of 8 hours.
There are a number of extreme conditions that can affect the duty cycling of the
compressors inside the generator. These extremes include very high ambient
temperatures, low supply voltages, a very high flow requirement and locations of high
altitude. Any one of these or a combination of a number of these extremes can be
evident in a customer site.
While the generator is designed to operate fully in these conditions it should be
noted that the effect of these extremes can force the compressors to run continually.
The compressors are fully capable of running continually with no detrimental effect,
however users may find the generator reaches its service interval quicker.
High Duty Indication Reset
If the compressors have been operating continually for a period of 8 hours the indicator
light will be illuminated. Once the compressors return to a cycling mode the indicator
light will automatically switch off. There is no manual intervention required.
Indication of Fault
In most installations the ‘HIGH DUTY’ indicator will never be illuminated. If your Genius
3045 Generator has been operating for a significant period of time, then suddenly
develops a ‘HIGH DUTY’ indication with no apparent change in environmental
conditions or flow requirements, it may be indicative of a problem with the system such
as an external leak or imminent compressor failure.
If this is the case you should contact Peak Scientific or your service provider.
It should be noted that the Generator will continue to operate so long as it can maintain
pressure during this indication.