background image

Page 28

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific/protected

.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at 

[email protected]

.

Product Warranty Registration

Contact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an 
alternative gas solution i.e. 
cylinders or bulk liquid?

Yes                 No

What gas requirements do 
you have in your lab?

Hydrogen             Nitrogen            Zero Air

Extend your cover with

Peak Scientific offer comprehensive gas generator after sales support packages.  
Peak [Protected] aftercare support can guarantee an on-site response within 
72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time 
fix rate.  See our enclosed Peak [Protected] leaflet for further information.

Important!

You have 1 month to register your Peak Scientific product from the date of installation. Once registered 

the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your 

generator, you must notify Peak Scientific immediately by emailing [email protected]

For generators that remain unregistered after 1 month from the shipment date, the warranty will be 

considered active from the date of factory dispatch.

* Complete Plan only

Go Online or Complete and Return

We know that registering any of your recently purchased products is not the 

first thing on your mind- but it is very important to both of us. Not all warranties 

are alike and Peak Scientific stand out against other gas suppliers as we offer a 
comprehensive, quick response, on-site warranty.  This means that in the very 

unlikely case that your gas generator develops a fault we have rapid support 

teams on-hand around the world who are able to come to your lab and get you 

back up and running in no time.

Register for your 

comprehensive 12 month on-site warranty 

with ease online at 

www.peakscientific.com/protected.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at [email protected].

Important!

You have 

1 month to register

 your Peak Scientific product from the date of 

installation. Once registered the warranty will be honoured for a period of 12 

months. If you wish to defer the installation of your generator, you must notify 
Peak Scientific immediately by emailing 

[email protected]

. For 

generators that remain unregistered after 1 month from the shipment date, the 
warranty will be considered active from the date of factory dispatch.

Содержание Genius 3010

Страница 1: ...Genius3010 3013 3020 3022 User Manual Rev 1 PN UM 0008 03 02 17 Genius 3010 13 20 22 User Manual...

Страница 2: ...ngs Kit Contents 14 Installation 15 Generator Environment 15 3010 3013 General Dimensions 16 3010 3013 Rear Connections 17 3020 3022 General Dimensions 18 3020 3022 Rear Connections 19 Electrical Conn...

Страница 3: ...ant information Users can refer to the contents page to find the relevant information Please review each of the following sections carefully Thank you for selecting Peak Scientific to meet your gas ge...

Страница 4: ...Generator designed as a plug and play system Economical More cost effective than any other gas supply method Convenient Gas on demand no hazards no need to worry about running out of gas The Genius 30...

Страница 5: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Страница 6: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Страница 7: ...uirements Low Voltage Directive 2015 35 EU EN 61010 1 2010 Electrical Equipment for measurement control and laboratory use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical...

Страница 8: ...19 EU These obligations are being met within the B2B compliance group Peak Scientific Instruments Ltd has developed all reasonable due diligence controls to ensure that our products comply with the p...

Страница 9: ...r 100 psi Maximum Outlet Flow Rate 64 L min 2 26 cfm Start Up Time 30 mins Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 1 x BSPP Drain Outlets 1 x BSPP Pressure Gauges 1 Electri...

Страница 10: ...let Flow Rate 64 L min 2 26 cfm Chip Cube Mode increased O2 content to 10 Start Up Time 30 mins Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 1 x BSPP Drain Outlets 1 x BSPP Pres...

Страница 11: ...r 100 psi Maximum Outlet Flow Rate 2 x independant outlet of 32 L min 1 13 cfm Start Up Time 30 mins Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 2 x BSPP Drain Outlets 1 x BSPP...

Страница 12: ...r 116 psi Maximum Outlet Flow Rate 2 x independant outlet of 32 L min 1 13 cfm Start Up Time 30 mins Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 2 x BSPP Drain Outlets 1 x BSPP...

Страница 13: ...e Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvr...

Страница 14: ...Tubing x 3m 2 Teflon Tubing x 3m 3 6mm PE Tubing x 3m 4 Compression Fitting x 1 5 6mm Push Fit Fitting x 2 6 Flow Control Silencer x 1 7 UK Mains Power Cable x 1 8 EU Mains Power Cable x 1 9 US Mains...

Страница 15: ...s affected by ambient conditions Note should also be taken to the proximity of Air Conditioning outlets These can sometimes give rise to pockets of air with high relative humidity Operation of the uni...

Страница 16: ...16 Generator Overview General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator WARNING 600 mm 23 6 850 mm 33 5 1322...

Страница 17: ...Page 17 3010 3013 Rear Connections Compression Fitting 6mm Push Fit Fitting Mains Cable...

Страница 18: ...Page 18 3020 3022 Rear Connections Compression Fitting 6mm Push Fit Fitting Mains Cable...

Страница 19: ...s classified as SAFETY CLASS 1 THIS UNIT MUST BE EARTHED Before connecting the unit to the mains supply please check the information on the serial plate The mains supply must be of the stated AC volta...

Страница 20: ...hing the output pressure gauges on the front panel This will climb to the factory set pressure as noted in the specifications Once this pressure is reached the compressors will continue to run until t...

Страница 21: ...cation starts again the system will detect the demand for gas and will automatically start again to suit the demand Generator Cycling The Generator is designed for the internal compressors to cycle Th...

Страница 22: ...e application can lead to a reduction in efficiency Tubing Lengths The diameter of the tubing which will be connected to the gas outlet is important and is determined by the length of tubing required...

Страница 23: ...ed Generators Kit Includes 4 x 0 01 Micron Filter Element 2 x RAC Filter Element 1 x Inlet Filter Element 2 x 3 2 Valve 4 x 2 2 Valve 6 x Plug In Relay 4 x Comp Service Kit 08 9408 1 Genius 3020 22 An...

Страница 24: ...lly for a period of 8 hours There are a number of extreme conditions that can affect the duty cycling of the compressors inside the generator These extremes include high ambient temperatures low suppl...

Страница 25: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preve...

Страница 26: ...e cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cle...

Страница 27: ...ng Check pressure gauges are showing normal pressure Contact your service provider The mass spec is reporting low pressure Contact your service provider Yellow SERVICE LED on front panel is on constan...

Страница 28: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 29: ...leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak to your...