Document Number: PD196-244R8
PD295-002
Page 14 of 28
PDi Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 USA PH 1-800-628-9870 FX 937-743-5664
Verifying and Troubleshooting Connections
The following steps verify the data connections between the STB and TV. These instructions assume
you have followed the previous connection and TV setup sections of this manual.
1. Power the Set Top Box.
2. Power the interface module.
3. Power the TV.
4. Examine the front mounted status lights on the PD295-002 interface module. It contains a Power
status light, a Set Top Box (STB) status light and a TV status light. Each light will turn green
when properly connected.
5. A dark (Off) status light indicates a problem. Blinking indicates data transfer.
NOTE: Please review “The TV does not control the STB” in the “Troubleshooting” section and “Flash
Power LED” in Setup for additional connection troubleshooting help.
POWER
STB LINK
TV LINK
SUGGESTIONS
OFF
OFF
OFF
1. Verify interface module is powered.
ON
OFF
ON
1. Verify IR Emitter cable is properly connected to the interface module.
ON
ON
OFF
1. Verify TV is powered.
2. Verify connections to interface module, TV wall plate, and TV CCI port.
3. Make
certain data cable is connected to the TV’s CCI port, not MTI or Ethernet
port.
4
. Verify TV standby power is set to “normal” and “Pro:Idiom” is set to “MTI Port”.
ON
OFF
OFF
1. Verify IR Emitter and CCI connections.
ON
ON
ON
1. All connections are proper.