LCD DISPLAY SYMBOLS   

 

 

 

 

 

 

 

 

-8.8.8.8    

LCD display reading

 

Continuity

 

 

  Low Battery 

 

 

Diode 

H

 

  Data Hold 

AUTO

 

  AutoRanging 

AC

 

  Alternating Current or Voltage 

DC

 

  Direct Current or Voltage 

 

n

 

nano (10

-9

) (capacitance) 

µ

 

micro (10

-6

) (amps, cap) 

m

 

milli (10

-3

) (volts, amps)    A   Amps 

k

 

kilo (10

3

) (ohms)  F Farads (capacitance) 

M

 

mega (10

6

) (ohms) 

 Ohms

 

Hz

 

Hertz (frequency) V Volts

 

%

 

Percent (duty ratio)                  

ºF

    Degrees Fahrenheit    

ºC

    Degrees Centigrade 

 

 

 

 

Function Buttons 

 
Mode Button 

 

Press the mode pushbutton to select 

 

 

 

 

 

the following functions; 

DC/AC Voltage, DC/AC Current 

Resistance, Diode, Continuity & 

Capacitance

   

 
Manual Range & Stroke 4/2(DIS),   
Hz, %, ms +, CYL Button 

Press to this button to select; 
STROKE 4, 2DIS, Hz ,%, ms+ ,   
CYL range & V/A/ Resistance manual 
Range   
 
Manual Ranging 

The meter turns on in the autoranging mode. 

Press the 

Range

 button to go to manual ranging. 

The display icon "

    

" will appear. Each press of the range button will 

step to the next range as indicated by the units and decimal point 

location. Press and hold the 

Range

 button for two seconds to return to 

autoranging. 

 

 
Data Hold   

The Data Hold function allows the   

meter to "freeze" a measurement for 

later reference.

 

1.  Press the 

HOLD

 button to “freeze” 

  the reading on the display. 

   The HOLD indicator, “

H

”, will appear 

   in the upper left corner of the display. 

2.  Press the 

HOLD

 button again to return 

     to normal operation. 

Auto Power Off

4

2

Auto Power Off

4

2

Auto Power Off

4

2

Содержание DM-930

Страница 1: ...1 0 DM 930 AUTOMOTIVE MULTIMETER INSTRUCTION MANUAL Auto Power Off 4 2...

Страница 2: ...t tested must be protected by a 20A fuse or circuit breaker Do not use the meter if it has been damaged Do not use any test leads if the insulation is damaged or if metal is exposed Safety Cont d Dang...

Страница 3: ...C AC DC20A 20A 20A DC AC 20 Amp measurement for 30 seconds maximum Getting Started This chapter will help you get started It describes the basic functions of the Meter Meter Basics 1 Digital LCD displ...

Страница 4: ...DIS Hz ms CYL Button Press to this button to select STROKE 4 2DIS Hz ms CYL range V A Resistance manual Range Manual Ranging The meter turns on in the autoranging mode Press the Range button to go to...

Страница 5: ...Pmin or Pmax indicator switches off Note If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected MAX MIN 1 Press the MA...

Страница 6: ...cation that has capacitors in the circuit be sure to turn the power OFF on the test circuit and discharge all capacitors Accurate measurement is not possible if external or residual voltage is present...

Страница 7: ...re performing any work Select the Capacitance CAP function with the function dial and MODE button Insert Black lead in COM terminal Red lead in V RPM terminal CAUTION When checking in circuit capacita...

Страница 8: ...nsure of the current draw IMPORTANT Turn OFF all power to the circuit or disconnect the circuit from the power source Connect The Red probe to the side of the circuit closest to the power source The B...

Страница 9: ...in COM terminal Red lead in V RPM terminal Connect the Black test probe to ground Connect the Red test probe to the signal wire circuit The illustration for a mixture control solenoid is shown with th...

Страница 10: ...ct black test probe to a good ground at the fuel injector or the negative vehicle battery post Connect red test probe to the fuel injector solenoid driver input on the jumper cable Start the engine A...

Страница 11: ...w battery indication The is displayed when the battery voltage drops below the operating level Measurement rate 2 times per second nominal Auto power off Meter automatically shuts down after approx 30...

Страница 12: ...Resistance Range Resolution Accuracy 400 0 0 1 1 2 of rdg 4 dgts 4 000k 1 1 0 of rdg 2 dgts 40 00k 10 1 2 of rdg 2 dgts 400 0k 100 4 000M 1k 40 00M 10k 2 0 of rdg 3 dgts Capacitance Range Resoluti on...

Страница 13: ...t leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door b...

Страница 14: ...still toggled ON Warranty This PDI product is warrantied to be free from defects in materials and workmanship for a period of two 2 years from the verified date of purchase During this warranty period...

Отзывы: