background image

 

   9                                                                       10

 

Meter Functions - Voltage (V)

 

 

Select the

 

Volts  “V” 

range with the 

rotary switch. 

The meter will automatically select 

best voltage (V) range.   

Select DCV or ACV with the function 

dial. 

 
Insert: 

 

Black lead in 

COM

 terminal. 

 

Red lead in 

V-

Ω

-RPM 

terminal 

Touch the Black probe to ground or to 
the negative (-) circuit 

Touch the Red probe to the circuit 
coming from the power source 

IMPORTANT: Voltage must be 
measuring in parallel (Red probe 
measuring circuit from power 
source). 

 

 

 

 

 

 

 

 

 

 

 

Meter Functions – Resistance (

Ω

)

 

   

 

IMPORTANT:

  If you are testing an 

application that has capacitors in the 

circuit, be sure to turn the power OFF 

on the test circuit and discharge all 

capacitors. Accurate measurement is 

not possible if external or residual 

voltage is present. 

 

Select the

 

Resistance  “

Ω

” 

range with the function dial. 

 

Select the

 

Resistance “

Ω

 

function 

with the Mode button. 

 

Please  Note:  the  DM-930  defaults to 

resistance.   

 

 

 

Insert:

                  

 

  Black lead in

 COM 

terminal. 

  Red lead in 

V-

Ω

-RPM

 terminal. 

 

Touch the test lead probes across the 

resistor to be tested. 

 
 
 
 
 
 

WARNING 

When measuring voltage, 
be sure the Red test lead is 
in the terminal marked “V”. 
If the test lead is in an Amp 
(A) or Milliampere (mA) 
terminal, you may damage 
your  meter  and  could be 
injured.   

 

¦ ¸

Auto Power Off

4

2

Black-

Red +

¦ ¸

Auto Power Off

4

2

Black-

Red +

Содержание DM-930

Страница 1: ...1 0 DM 930 AUTOMOTIVE MULTIMETER INSTRUCTION MANUAL Auto Power Off 4 2...

Страница 2: ...t tested must be protected by a 20A fuse or circuit breaker Do not use the meter if it has been damaged Do not use any test leads if the insulation is damaged or if metal is exposed Safety Cont d Dang...

Страница 3: ...C AC DC20A 20A 20A DC AC 20 Amp measurement for 30 seconds maximum Getting Started This chapter will help you get started It describes the basic functions of the Meter Meter Basics 1 Digital LCD displ...

Страница 4: ...DIS Hz ms CYL Button Press to this button to select STROKE 4 2DIS Hz ms CYL range V A Resistance manual Range Manual Ranging The meter turns on in the autoranging mode Press the Range button to go to...

Страница 5: ...Pmin or Pmax indicator switches off Note If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected MAX MIN 1 Press the MA...

Страница 6: ...cation that has capacitors in the circuit be sure to turn the power OFF on the test circuit and discharge all capacitors Accurate measurement is not possible if external or residual voltage is present...

Страница 7: ...re performing any work Select the Capacitance CAP function with the function dial and MODE button Insert Black lead in COM terminal Red lead in V RPM terminal CAUTION When checking in circuit capacita...

Страница 8: ...nsure of the current draw IMPORTANT Turn OFF all power to the circuit or disconnect the circuit from the power source Connect The Red probe to the side of the circuit closest to the power source The B...

Страница 9: ...in COM terminal Red lead in V RPM terminal Connect the Black test probe to ground Connect the Red test probe to the signal wire circuit The illustration for a mixture control solenoid is shown with th...

Страница 10: ...ct black test probe to a good ground at the fuel injector or the negative vehicle battery post Connect red test probe to the fuel injector solenoid driver input on the jumper cable Start the engine A...

Страница 11: ...w battery indication The is displayed when the battery voltage drops below the operating level Measurement rate 2 times per second nominal Auto power off Meter automatically shuts down after approx 30...

Страница 12: ...Resistance Range Resolution Accuracy 400 0 0 1 1 2 of rdg 4 dgts 4 000k 1 1 0 of rdg 2 dgts 40 00k 10 1 2 of rdg 2 dgts 400 0k 100 4 000M 1k 40 00M 10k 2 0 of rdg 3 dgts Capacitance Range Resoluti on...

Страница 13: ...t leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door b...

Страница 14: ...still toggled ON Warranty This PDI product is warrantied to be free from defects in materials and workmanship for a period of two 2 years from the verified date of purchase During this warranty period...

Отзывы: