In order to fasten the conditioning, the following proceedings are possible: 

Spaced insertion of the sword sensor 

o

Insert the sword-sensor into the stack for only approx. 10 cm, and push it
a few more centimetres into the stack every 10 seconds.
In case of a high temperature difference repeat this action – if necessary
several times!

o

If  you  use  the  sword  sensor  holder,  please  ensure  that  both  the  sword
sensor  and  the  sword  sensor  holder  are  adjusted  to  the  surrounding
temperature of the material.
In this case insert the sword sensor holder at frequent intervals and leave
the sword sensor in the sword sensor holder for an appropriate period.

Care instructions 

Do  not  drop  the  instrument  or  expose  it  to  excessive  temperatures.  The 
instrument is not waterproof. Do not immerse the sensor in liquid. 
The intervals for checking the instrument depend on your operational 
demands and the required level of accuracy. In general the drift of the sensor 
according  to  the  degree  of  use  (constant  humidity  or  use  within  the 
whole moisture  measuring  range)  is  beneath  0.5  %  per  year. 

Changing the batteries 

First  of  all  remove  the  rubber  protection  cover.  For  that,  hold  the 
rubber protection  cover  at  the  upper  side  and  pull  it  over.  If  your 

device

 is provided  with  an  optional  USB  port,  you  have  to  remove  the 

protection cap before.  Press  with  your  finger  onto  the  arrow  of  the  battery 
cap  and  pull  it back. 
Remove the empty batteries. Put four new 

1.5 Volt AA Alkaline batteries

 

in the device. Make sure that the position of the battery poles is correct. 
Press down the batteries and close the cap. 

Exemption from liability 

For  miss-readings  and  wrong  measurements  and  of  this  resulting  damage 
we  refuse  any  liability.  This  is  a  device  for  quick  determination  of  moisture. 
The  moisture  depends  on  multiple  conditions  and  multiple  materials. 

Содержание RH5

Страница 1: ...User Manual RH5 Humidity Measuring Device with Sword Sensor Version 1 0_en PCE Instruments 2016...

Страница 2: ...orm the sensor For heavy stacks and rolls please use the optionally available sword sensor holder and the tool for removing the sword sensor holder Measurement To switch on the instrument press the ke...

Страница 3: ...ative humidity the excessive moisture would condense or form fog Dew point temperature The dew point indicates the temperature that the not completely saturated air has to reach in order to be complet...

Страница 4: ...page 4 Design of the device batteries slot flipside measuring value calibration curve ON OFF button temperature selection of calibration curves air humidity and temperature sensor Option interface...

Страница 5: ...r ON OFF Switch upper Switch lower Save Hold Autolog Watch saved data Enter suppliers data Menu Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left Yes No Shift OK Edit...

Страница 6: ...ase press the button Supplier s data can also be entered on the PC subsequently Switching on the display lighting Press the key briefly the display lighting switches off automatically after approx 20...

Страница 7: ...until you reach the menu see image on the right Then choose Send Logs and confirm by pressing the key Now choose Manual Logs or Auto Logs and confirm with again All saved logs will be transferred to...

Страница 8: ...e cable has to be plugged in at the printer Switch on the printer by pressing Now the green LED is blinking If it does not blink please change the batteries and try again Press the button at your devi...

Страница 9: ...temperature of the different components is to store all components together in a room with only small temperature fluctuations minimum over night better for 24 hours Components of calibration equipme...

Страница 10: ...carefully and proceed as follows Conditioning the sensor To achieve best results let the sensor adjust for two hours The temperature has to be between 20 C and 26 C If the shown measuring value diffe...

Страница 11: ...factory calibration as follows Reset to factory calibration 1 Press the button two times to reach the menu point Options 2 Select the menu item Reset using the button and confirm by pressing 3 Enter...

Страница 12: ...ervals for checking the instrument depend on your operational demands and the required level of accuracy In general the drift of the sensor according to the degree of use constant humidity or use with...

Страница 13: ...emove the batteries For eventual resulting damages we cannot provide any warranty In case of a faulty device please contact PCE Instruments Optional accessories PC interface for printing saved data on...

Страница 14: ...page 14 Notes...

Страница 15: ...h German French Italian Spanish Russian 4 pcs 1 5Volt AA Alkaline batteries for approx 1800 measurements after approx 4 minutes 30 mA with display lighting 128 x 64 matrix display with LED backlightin...

Страница 16: ...ing To demonstrate the importance of temperature adjustment the table below shows measuring errors due to a temperature difference of only 1 C 1 8 F between the measuring instrument and the substance...

Отзывы: