Thank you for purchasing a gas detector from PCE Instruments. 

1  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. PCE Instruments 
cannot be held liable for any damage or injuries caused by non-observance of the manual.

 

 

 

The device must only be used as described in this instruction manual. If used otherwise, this can 
cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative humidity, 
…) are within the ranges stated in the technical specifications. Do not expose the device to 
extreme temperatures, direct sunlight, extreme humidity or moisture.

 

 

When the air quality meter is exposed to extreme heat, fire and explosions as well as 
deformations of the device are very likely.

 

 

Do not expose the CO

analyser to any impact, shocks or vibration. 

 

The case should only be opened by qualified PCE Instruments personnel. Touching the electrical 
conductor inside the instrument can cause electric shocks. 

 

Never use the meter when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no 
abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. Using the 
wrong mains adaptor can cause damage to the device as well as fatal injuries of the user. 

 

The mains adaptor should be fixed tightly with the elastic plug lock, so that it can only be 
removed using mechanical tools.

 

 

If you wish to connect a fan to the potential-free contacts of the sensor unit, make sure that the 
fan has its own external power supply. Otherwise, the fan will not work. This can cause 
dangerously high CO

2

 concentrations in the monitored area.

 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not use the 
device. 

 

Do not use the instrument in explosive atmospheres. 

 

Pay special attention to the “ESC” indication in the display. If it appears, adopt protective 
measures before entering the room where the sensor unit has been installed. 

 

Check the cable connection between the sensor unit and the remote display unit thoroughly. The 
cable is connected to the remote display unit’s input, coming from the sensor unit. 

 

Communication between the sensor unit and the remote display unit should work flawlessly. 
Therefore, you should use the “DIAG” function to test flawless communication. 

 

The limit values for the measuring variables as stated in the specifications must under no 
circumstances be exceeded. 

 

Non-observance of the safety notes can lead to damage of the device or injuries of the user. 

 

Moreover, observe the applicable national health and safety regulations and those set up by the 
relevant trade associations in your country, as well as any relevant regulations for safe and 
professional operation. Particularly, make sure to comply with your national accident prevention 
regulations for the handling of gases. 

 
This instruction manual is published by PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms which can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Содержание PCE-WMM 50

Страница 1: ...iter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busine...

Страница 2: ...n 6 3 1 Device 6 3 2 Display 9 4 Getting started 10 4 1 Preparation 10 4 2 Power connection 11 5 Operation 12 5 1 Further measuring functions 12 5 2 Settings 13 6 Maintenance 14 6 1 Repair cleaning an...

Страница 3: ...tightly with the elastic plug lock so that it can only be removed using mechanical tools If you wish to connect a fan to the potential free contacts of the sensor unit make sure that the fan has its o...

Страница 4: ...250 V AC max 2 A Alarm thresholds Alarm 1 0 5 1 1 5 2 Alarm 2 1 5 2 2 5 3 3 5 4 Menu items Function test of connection between sensor unit and remote display unit calibration switching between C and F...

Страница 5: ...nal digital display to measure temperature in C and F LEDs for operation alarms 1 2 and monitoring of voltage supply Display elements Function test Reset menu selection Enter shifting between C and F...

Страница 6: ...tential free contact which can for instance activate a fan which reduces the increased CO2 concentration in the room concerned Sensor unit A LC display B Yellow LED error indication C Red LED 2 AL2 D...

Страница 7: ...between sensor unit and remote display unit CAL Calibration of gas detector ReFactSet Reset to factory default settings You can set two alarm thresholds AL1 AL2 1 Alarm threshold Selectable threshold...

Страница 8: ...te display unit O Green LED power supply P Red LED 1 AL1 Q Red LED 2 AL2 R Yellow LED error indication S LC display T Enter key U Mode key V RJ45 connection Output W RJ45 connection for sensor unit In...

Страница 9: ...d LED 1 flashes the buzzer sounds and the potential free contact closes if the red and blue cables are connected or closes if the white and blue cables are connected Second alarm threshold If the CO2...

Страница 10: ...2 concentration before entering the room where the sensor unit is located The connection between both devices can be checked by using the DIAG function which is described in the further course of this...

Страница 11: ...blue cables are connected the contact closes B blue cable R red cable W white cable 1 power connection fan 2 fan 4 2 Power connection Connect the mains adaptor to the wall socket Attach the elastic sa...

Страница 12: ...larms are triggered early 5 1 Further measuring functions DIAG function The communication between the sensor unit and the remote display unit should be checked on a regular basis by using the DIAG fun...

Страница 13: ...actory default settings are restored after the confirmation 5 2 Settings Lock unlock The gas detector has an automatic lock function to prevent the settings from being changed unintentionally If you w...

Страница 14: ...e key The following options are available 1 5 2 2 5 3 3 5 4 Select the desired option and press the Enter key to confirm 6 Maintenance 6 1 Repair cleaning and maintenance Repairing Do not try to repai...

Страница 15: ...ubber cap on the gas input M to prevent water from getting into the device Maintenance The communication between the sensor unit and the remote display unit should be checked on a regular basis by usi...

Страница 16: ...f this does not help please contact our customer support Er7 Internal data transfer error Er7 flashing LED FLT flashing buzzer makes noise Er7 flashing LED FLT flashing buzzer makes noise Unplug the p...

Страница 17: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 9 Contact If you have any questions about our rang...

Отзывы: