background image

 
 
 
 

e. Memory 
 
e-1. Location 

The gauge has a memory capacity of 4000 measurements which location can be from 0000 to 3999. After 

taking every measurement, press 

 key to store the value with a location number. You can also select an 

initial number for beginning to store the value and the next number will be followed automatically by following 
measurements. 

- Press 

 key into“ Location ”state 

- Press 

 or 

 to select desired number as initial location 

- Press 

 key to enter/confirm 

If you want to read the stored value in memory, 

Press 

 key to read one by one data according to the above procedure, select desired initial number. Then 

the desired group of value can be readable beginning from this initial number.

 

 
e-2. Delete Memory 

 
Delete the data in memory which locations are selected. 
 

f. Limitation 

- Press 

 key into“ Limitation ”state 

- Press 

 or 

 to select desired low limitation and high limitation  

- Press 

 key to enter/confirm 

  When the measuring value is lower or higher than the limit value a sign “L” or “H” will appear on the right top of  
  LCD. 
    

g. Average Measurement  

You can get mean values by 2 to 9 times on TG 200 thickness gauge 

- Press 

 key into “ Average ”state 

- Press 

 to select desired average times (2 to 9) 

- Press 

 key to enter/confirm 

When complete measuring once, you must wait about 3 seconds, the gauge will calculate measuring data and 
average times will decrease 1 appearing on the right top of LCD. When average times is zero, the gauge will 
show the averaged value on LCD. 
 

h. Print Out  

If you want to print the stored values, you must determent the initial location number and the end location 
number, 

- Press 

 key into “Print” state 

- Press 

 or 

 to select desired initial and end location number. 

- Press

 key to enter / confirm 

The gauge will print the stored value in memory from initial location number to end location number 
automatically. 
 

Содержание PCE-TG200

Страница 1: ...9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com Material Thickness Meter ...

Страница 2: ...3 Measurement 3 4 Calibration 3 5 Set up 3 a Measurement 4 b Velocity Rate 4 c Probe Setting 4 d Resolution 4 e Memory 5 f Limitation 5 g Average Measurement 5 h Print Out 5 i Default 6 6 Data print out optional 6 7 Technical data 6 8 Appendix 7 ...

Страница 3: ... 3 Measurement There are three ways to go into measuring mode Switch on the gauge Press power key escape from MENU Measurement 4 Calibration When initially switch on the gauge or get an error value instead of 4 00mm when velocity rate is 5920 m s if take measurement of test block attached on the gauge which correct value should be 4 00mm or other standard test block the gauge needs to be calibrate...

Страница 4: ...e the thickness as the same as the value of sample that is measured Press key again the gauge will store the velocity rate automatically c Probe Setting The gauge provides three types of probe for user Press key into Probe selecting state Press or to select probe 1 normal probe PT 08 2 small diameter probe PT 06 3 low frequency probe ZT 12 4 High Temperature probe GT 13 Press key to enter confirm ...

Страница 5: ...on state Press or to select desired low limitation and high limitation Press key to enter confirm When the measuring value is lower or higher than the limit value a sign L or H will appear on the right top of LCD g Average Measurement You can get mean values by 2 to 9 times on TG 200 thickness gauge Press key into Average state Press to select desired average times 2 to 9 Press key to enter confir...

Страница 6: ...ate 1000 9999 m s 0 0393 0 3936 inch μs Measuring range 0 65 250 0 mm 0 026 9 843 inches Resolution 0 1 mm 0 01 mm or 0 01 inch 0 001 inch Tolerance 0 65 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 3 Power supply two 1 5V AAA dry cells Size 61 108 28 mm w h d Weight 150g with batteries Operating temperature 10 ºC to 50 ºC Storage temperature 20 ºC to 60 ºC Probe types and measuring rang S...

Страница 7: ...0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polyethylene 1950 0 070 Polystyrene 2350 0 092 Steel 5920 0 233 Stainless Steel 5740 0 226 Titanium 5990 0 237 Water 1490 0 059 Zinc 4210 0 165 NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases ...

Отзывы: