Start-up procedure 

Before using the device for the first time, charge the battery sufficiently (for at least 4 hours). Insert the 
battery correctly into the camera until you hear a clear clicking sound. Then connect the fuse to the 
bottom side of the battery. Open the cap in front of the lens and put it on the top side of the camera. Due 
to magnetism, the cap will not fall down during the measurement and interfere with it. After this, push the 
power button on the right-hand side below the LC display for approx. 4 seconds. When the device is 
completely switched on, you can start with your measurement. 
 

5.5 

Display 

The display then shows the infrared image along with the colour palette on the right-hand side and the 
adjustable emission rate in the upper left corner of the display. On the right next to the emission rate, the 
temperature of the object pointed at by the hair cross in the middle of the display is indicated. On the 
upper right-hand side, time and battery level are displayed. 
 

5.6 

To save images 

By pushing the Trigger button on the front side of the infrared camera, the image shown on the display 
can be saved on the SD card if an SD card is inserted. Make sure that the SD card is inserted if you want 
to save your images. If this is not the case and the user still pushes the Trigger button, the display will 
indicate “! No SD card”. If the images have been successfully saved on the SD card, the device will 
indicate “Saving”. 
 

5.7 

Settings 

You can make various settings to the device. To get to the menu, push the select left button directly under 
the LCD. After this, the menu will open and you can decide what settings you wish to make by selecting 
with the “+” and “-” buttons. By pushing the select button again, you can select the appropriate adjustment 
range and use the sub-menus in the same way as the main menu. The following sub-menus are 
available: 
 

5.7.1 

Main display 

In this menu, the display only shows the image, the colour palette, the emissivity, the hair cross and the 
battery level. If you want to make a measurement where the hair cross is located, you must pull the 
trigger. The temperature measured at that point will also be indicated. This will remain on the LCD until a 
new measurement is triggered. If you push the select left button again, the device will show all information 
on the display again. 
 

5.7.2 

Temperature analysis 

For temperature analysis, you can choose between different measurement functions. You can select the 
functions “point” (standard), “range max.”, “range min.”, “over” and “below”. If you choose point 
measurement, you measure the point shown by the hair cross. When you choose “range max.”, the 
display will show a range in the form of a square. Inside the square, the hair cross will now appear and 
jump to the warmest spot inside the square. The measurement function “range min.” works the same way 
with the only difference that the hair cross will show the coldest spot in the image

. The functions “over” 

and “below” are set point measurements. The user can set the measurement value. If you have selected 
the “over” function, the range above the chosen temperature is indicated in green. When you have 
selected the “below” function, the opposite is the case. If the camera detects objects the temperature of 
which is below the set value, these objects are indicated in red. 
 

5.7.3 

Emissivity setting 

The emissivity is set by the user here. The most common materials are already pre-set. In case you wish 
to set another emissivity, you must choose “user setting”. Here you can set an emissivity yourself. 
 

Содержание PCE-TC 30

Страница 1: ...us PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Southampton Hampshire United Kingdom SO31 4RF Tel 02380 98703 0 Fax 02380 98703 9 info industrial needs com www pce instrumen...

Страница 2: ...common material emissivities 6 5 4 Start up procedure 7 5 5 Display 7 5 6 To save images 7 5 7 Settings 7 5 7 1 Main display 7 5 7 2 Temperature analysis 7 5 7 3 Emissivity setting 7 5 7 4 Palette 8 5...

Страница 3: ...ake sure that the device is also protected from splashing water The case must only be opened by qualified personnel of PCE Instruments Otherwise the warranty will become void The instrument should nev...

Страница 4: ...Tmin HOLD function Tmax Tmin Display LCD 320 x 240 pixels Thermal sensitivity 80 mK Lens 8 mm Digital zoom 3 x Field of view FOV 18 5 x 18 5 Frequency 50 Hz Working temperature 0 50 C Interface micro...

Страница 5: ...Manual 5 4 Device description 4 1 Camera components 4 2 Buttons 4 3 Display...

Страница 6: ...harger There is also the possibility to charge the battery via a charger which is however not included in the delivery and can be purchased separately 5 2 Data transfer You can easily transfer your me...

Страница 7: ...by selecting with the and buttons By pushing the select button again you can select the appropriate adjustment range and use the sub menus in the same way as the main menu The following sub menus are...

Страница 8: ...or this purpose the auto mode and the lock mode factory default setting If lock mode is on the scale has fixed extremes In auto mode the limits are variable and adapt to their environment 5 10 To disp...

Страница 9: ...tware configuration 5 12 2 1 Hardware configuration minimum requirements Requirement Details CPU Pentium 4 2 4 GHz RAM 512 MB and more Graphic card NVIDIA GeForce 5200 125 MB Hard disc 40 GB and more...

Страница 10: ...our computer will then show an additional virtual drive called GUIDE_IR The pictures taken by the camera are saved under DCIM under PICTURE You must then copy the data from that location and save them...

Страница 11: ...to create the folder You can create a subfolder under each folder 5 12 3 2 3 To delete folders Click to select the folder to be deleted The symbols and appear next to the folder When you click on you...

Страница 12: ...12 3 2 5 Note on commented images In case you see a in connection with the image properties this means that there is a comment along with the selected image If the selected image comes with a this me...

Страница 13: ...n the picture you would like to select 2 If an image has already been loaded you can click on to choose another one 3 Select an image in normal mode and pull it to the analysis interface with the mous...

Страница 14: ...analysis tools You have the possibility to add analysis tools to the image by means of the software To add spots Click on The spot will then be displayed like this To add lines Click on The line will...

Страница 15: ...ick on The dashed line will be displayed like this Rectangle Click on The rectangle will be displayed like this Circle Click on The circle will be displayed like this Polygon Click on The polygon will...

Страница 16: ...e dimensional display When you click on the image is displayed three dimensionally This makes it possible for you to turn it by means of the mouse You can also increase or decrease the size of the ima...

Страница 17: ...mits are restored Click on to save the colour palette as you have set it 5 12 3 3 5 Emissivity You can choose a value from the analysis information which you have to double click on Then a new window...

Страница 18: ...Manual 18 5 12 3 4 Report creation...

Страница 19: ...as an infrared image as well as a normal image 5 12 3 4 2 To add letters The user can easily make changes to the template adds texts fields to the template adds a comment to the template adds a highli...

Страница 20: ...pen the template database You can create a new template by clicking on You can delete it by clicking on The template currently used is highlighted in green 5 12 3 4 5 To export reports By clicking on...

Страница 21: ...and Chinese as software language 5 12 3 5 2 Units The software offers the possibility to adjust temperature and length units in line with user needs and purposes As temperature units you can choose b...

Страница 22: ...in what way You can select either both extremes the maximum temperature the minimum temperature or none 5 12 3 5 4 Report Here you can make a standard setting of what is to be shown in the report You...

Страница 23: ...Manual 23 5 12 3 5 5 Others Further settings regarding updates and popup windows can be adjusted here...

Страница 24: ...ents All products are CE and RoHs approved 7 Contact If you have any questions about our range of products or measuring instruments please contact PCE Instruments 7 1 PCE Instruments UK By post PCE In...