22
Parameter
Range/value
Decimal point
000.00
Averaging time
1 s
Upper measurement overflow
99999
Lower measurement overflow
-19999
Individual characteristic
enabled
Parameter
a
of the individual characteristic
5
Parameter
b
of the individual characteristic
0
Table 10
EXAMPLES OF ORDER:
Example 1
The code:
N24Z - 2 1 04 00 E 0
means:
N24Z
– digital meter with four digits for a.c. signals,
2
– input signal: 250 V a.c. (acc. to the table 8),
1
– supply voltage: 230 V a.c.,
04
– with the unit: V (acc. to the table 9),
00
– standard version,
E
– English language,
0
– without extra quality inspection requirements.
Example 2
(custom-made version)
The code:
N25S - 1 4 02 XX E 1
means:
N25S
– digital meter with 5 digits for d.c. signals
1
– input signal: 0…20 mA (acc. to the table 8),
4
– supply voltage: 85…253 V a.c., with the 24 V/30 mA supply
input for external transducers,
02
– with the unit: % (acc. to the table 9), with display indications:
0…100.0,
XX
– custom-made, mentioned in the table 10,
E
– English language,
1
– with an extra quality inspection certi
fi
cate.
Example of additional information for non-standard settings