PCE Instruments PCE-910 Скачать руководство пользователя страница 4

Manual 

 

3  Specifications 

Model 

 

PCE-910 

PCE-917 

PSI 

Range 

±29.00 

101.50 

 

Resolution 

0.01 

0.05 / 0.1 

Mbar 

Range 

±2000 

±7000 

 

Resolution 

inH2O 

Range 

±802.0 

±2800 

 

Resolution 

0.5 

mH2O 

Range 

±20.40 

±70.00 

 

Resolution 

0.01 

0.05 

inHg 

Range 

±59.00 

±206.0 

 

Resolution 

0.02 

0.1 

mmHg 

Range 

±1500 

±5250 

 

Resolution 

Torr 

Range 

 

Resolution 

Pa / kPa 

Range 

 

Resolution 

atm 

Range 

±1.974 

±6.905 

 

Resolution 

0.001 

0.005 

kg/cm² 

Range 

±2.040 

7.000 

 

Resolution 

0.001 

0.005 

Accuracy 

 

±2 % (full range) 

Reproducibility 

 

±1 % 

Measurement 
sequence 

 

0.8 s 

Min- Max- Peak- Hold 

 

Yes 

Interface 

 

RS-232 

Power supply 

 

1 x 9 V battery PP3 

Material of case 

 

plastic 

Dimensions of case 

 

180 x 72 x 32 mm 

Weight 

 

210 g 

 

Содержание PCE-910

Страница 1: ...ents UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce inst...

Страница 2: ...Safety notes 3 3 Specifications 4 4 System description 5 5 Instructions 6 5 1 Measurement 6 5 2 Auto Power Off 6 5 3 RS 232 data interface 6 5 4 Battery replacement 6 6 Disposal 6 7 Contact 7 7 1 PCE...

Страница 3: ...cate has a check protocol and contains the name of the company which means that it can be incorporated into the company s pool of internal test tools according to ISO standards 2 Safety notes Please r...

Страница 4: ...nge 59 00 206 0 Resolution 0 02 0 1 mmHg Range 1500 5250 Resolution 1 5 Torr Range Resolution Pa kPa Range Resolution atm Range 1 974 6 905 Resolution 0 001 0 005 kg cm Range 2 040 7 000 Resolution 0...

Страница 5: ...play 1 2 On Off key 1 3 HOLD key 1 4 ZERO key 1 5 MAX MIN key 1 6 UNIT selection key 1 7 Connection for hose adaptor 1 1 8 Connection for hose adaptor 2 1 9 RS 232 interface 1 10 Battery compartment 1...

Страница 6: ...the MIN symbol in the display You can deactivate this function by pressing and holding the MAX MIN key 1 5 for 2 to 3 seconds 5 2 Auto Power Off To save energy the device has an Auto Power Off functio...

Страница 7: ...contact PCE Instruments 7 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 7 2 P...

Отзывы: