DATA HOLD FUNCTION 

 

While in normal mode, press "HOLD" +             T/DP  ,only the T1, RH will be held. 

Press "HOLD"again to release. 

 

While in normal mode, press "HOLD" +              T2 /WB ,only the T2 will be held. 

Press "HOLD"again to release. 

 

DEW POINT FUNCTION 

 

Press              button until “DP” appears on display. Select to display dew point, T1 (air 

temp.) or delta T (T1-T2) in any mode while the meter is on. See Fig. E 

 

 

 

 

 

WET BULB FUNCTION 

 

 

Press              until Wbappear on the LCD. User will see “Wb” temperature indicated on the 

display. See Fig. E. 

 

Ex. TEMPERATURE FUNCTION 

 

Plug the external probe into the meter. Press               button until “T2” appears on display. 

Unit will now display external probe temperature. See Fig. 3 

 

 

 

Содержание PCE-310

Страница 1: ...1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire South...

Страница 2: ...nable cap to protect sensor External Temp probe Triple LCD digital display T1 T2 T2 DP function Model 8716 Data Hold to capture readings Pocket size easy to fit in pocket Low battery indication Fast r...

Страница 3: ...3 WARNING External probe port IMPORTANT BE SURE TO OPEN THE SENSOR PROTECTION CAP BEFORE STARTING THE MEASUREMENT IN ORDER TO GET ACCURATE VALUE FOR ALL MODELS CONTROLS AND INDICATORS...

Страница 4: ...n itself off after 10 minutes To override Auto Power Off function press ON OFF HOLD while the meter is off When n appears See Fig A release HOLD button Meter is now in Non Sleep Mode For PCE 310 the a...

Страница 5: ...ON Press button until DP appears on display Select to display dew point T1 air temp or delta T T1 T2 in any mode while the meter is on See Fig E WET BULB FUNCTION Press until Wbappear on the LCD User...

Страница 6: ...than two seconds to clear current reading from memory WARNING While checking MIN MAX value for EX T2 and don t replace probe otherwise you will get error code displayed If you don t plug the probe int...

Страница 7: ...s displayed as that means the values are invalid in the calibration process After 30 min the flashing will stop to indicate the procedure is finished 3 Move the sensor to 75 salt bottle and press more...

Страница 8: ...auto power off function Er 1 Circuit error in RH measurement channel return the meter to the store for repairing Er 2 Circuit error in Internal temperature measurement channel return the meter to the...

Страница 9: ...son When requiring a RA Return Authorization please include data regarding the defective reason the meters are returned along with good packing to prevent any damage in shipment and insured against po...

Отзывы: