background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

End Recording:    End recording when selected. 

VIEW FILE: 

If the View option under FILE in the Main Window is selected, a view window will be shown as above, and the 

users  can  review  your  ASCII  data  file.    If  a  printer  is  connected  to  the  PC,  users  can  print  out  content 

selectively. 

File:  Open user’s data file by selecting this menu.  Users will be asked to enter file name.  After the name 

being entered, program will read in one block of data.  Number of records in one block depends on the 

memory size of PC.  The bigger memory, the more records in one block. 

Blocks Read: 

    Indicate how many blocks of records have been read. 

Records Read: 

    Indicate how many records have been read. 

Chars./Record: 

    Indicate how many characters in one record. 

Current Block: 

    Indicate the current block number being reviewed. 

Selected: 

    Indicate the current record number being selected. 

Plotting Data from File 

If the "Plot Data from File" option under FILE is selected in the Main Window, a Plot Window will be shown, and 

the users can plot curve of your data file.  If a printer is connected, users can print out the curve. 

File:   

Open the file to plot data from 

Select: 

Select one of the items Velocity, Temperature, Flow, or Area to plot 

Scale:        Set the scale of Y-axis. 

X Label:  Users can select sequence number (1,2,3,4,...) or time (12:00:01, 12:00:05, ...) as X-axis label. 

Title:        Enter the title for X-axis, Y-axis, or Graph. 

Grid:         Draw Horizontal, Vertical grids or both. 

Zoom: 

Zoom into the graph.  The zoom size is limited to 3600 points. 

Statis:      Statistics. This function allows users to plot average value, 

 
 
 

 

Содержание PCE-007

Страница 1: ...el 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com ...

Страница 2: ...One Data One Shot Sampling Time 0 7 3 9 To Record Data Continuously Sampling Time 0 7 3 10 To Read Data Stored in Memory Sequentially 7 3 11 To Read Data Stored in Memory Randomly 7 3 12 To Send Data Out to PC through RS 232C AVM 07 7 3 13 The Data Format of 15 Data Sent Out to RS 232 7 3 14 Down Load Data to Personal Computer AVM 07 8 3 15 Data Format Stored in Memory 8 4 WindowsTM Application Pr...

Страница 3: ...Shot or Continuous Recording z Sampling time set by keypad z RS 232C interface PCE 007 z C F z Ergonomic and easy to use design z Read while measuring detached vane z Large 17mm 3 digits LCD Liquid Crystal Display z Hold Max Min function z Build in low battery indicator 2 Front Panel Description Figure 1 1 LCD 2 Detached Vane 3 On Off Button 4 RS 232C Interface 5 Function and Numerical Keypad ...

Страница 4: ...ll appear RS 232 When the RS 232 function is enabled this symbol will appear ft2 This symbol is used to indicate free area in square feet when in flow function m2 This symbol is used to indicate free area in square meter when in flow function C This symbol is used indicate temperature in Celsius F This symbol is used to indicate temperature in Fahrenheit CFM This symbol is used to indicate unit in...

Страница 5: ... more accurate results try to keep the axis of the vane within 20 of the wind direction 3 2 Measurement of Wind Air Temperature 1 When the meter is measuring wind velocity the temperature of wind is measured at the same time 2 Select C or F by pressing C F button number 6 3 Let the wind pass through the vane A thermocouple is built into the center of the vane 4 Read the temperature reading from LC...

Страница 6: ...e the approximate wind direction 8 Move around the center of free area to measure the maximum velocity of wind velocity The anemometer will record the maximum value and use it to calculate the wind flow 9 For more accurate results try to keep the axis of the vane within 20 of the wind direction 3 5 Measurement of Wind Air Flow Average Air Flow 1 Press the on off button to turn on the anemometer 2 ...

Страница 7: ...ry Sequentially 1 Press the READ button number 7 to read data stored in memory sequentially 2 The RECORD NUMBER will be displayed in the upper LCD before the data is displayed The data will roll over to the first record if the last record is read 3 To exit READ mode press RESET button number 8 3 11 To Read Data Stored in Memory Randomly 1 Once anemometer is in READ mode users can still read a rand...

Страница 8: ...778 Byte10 768 Reserved Byte769 784 Record 1 16 bytes per record Byte769 Digit 0 least significant in lower LCD Byte770 Digit 1 in lower LCD Byte771 Digit 2 in lower LCD Byte772 Digit 3 most significant in lower LCD Byte773 Digit 0 least significant in upper LCD Byte774 Digit 1 in upper LCD Byte775 Digit 2 in upper LCD Byte776 Digit 3 most significant in upper LCD Byte777 Upper LCD decimal point b...

Страница 9: ...ion port is setup a main window will be displayed on the screen as below Sample The value under SAMPLE is the sampling time Temperature Temperature of air or wind Option Display option of anemometer MAX MIN AVE 2 3V max Unit Display units of velocity or flow m s ft min knot mph kmh CFM or CMM Value The value under VALUE is the reading from the anemometer Range The text displayed under RANGE is the...

Страница 10: ...ars Record Indicate how many characters in one record Current Block Indicate the current block number being reviewed Selected Indicate the current record number being selected Plotting Data from File If the Plot Data from File option under FILE is selected in the Main Window a Plot Window will be shown and the users can plot curve of your data file If a printer is connected users can print out the...

Страница 11: ...600 data STATIS will be disabled Clear Clear the graphic screen Print Print out the curve if a printer is connected to PC DISPLAY DISPLAY menu has four options DIGITAL ANALOG LIST and GRAPHIC DIGITAL If this option is selected or CTRL D are pressed a window which emulates multimeter s LCD display shall appear on the screen ANALOG ...

Страница 12: ...u the graphics will be printed through any printer connected to the PC The SCALE menu allows user to set the minimum and maximum value for the Y vertical axis Option If you select Option a pull down menu will show three options Sample Rate Baud Rate Upper Limit Enter upper limit If upper limit is exceeded a OVER message will be displayed in screen Lower Limit Enter lower limit If displayed value i...

Страница 13: ...ve 10 seconds to press the key of D LOAD number 5 of anemometer When the D LOAD key of anemometer is pressed all the data stored in the memory of anemometer will be sent to PC Program will convert all the coded data to a ASCII file under the name entered by users 5 Specifications 23 5 C Range of Wind Velocity Units Range Resolutio n Threshold Accuracy m s 0 0 45 0 0 01 0 3 3 0 1 ft min 0 8800 2 60...

Страница 14: ...1 9999 Bearing Sapphire jewel bearing Temperature sensor K type thermocouple Mounting Nut 1 4 x 20 Operating Temperature Meter 0 C 50 C 32 F 122 F Vane 0 C 60 C 32 F 140 F Operating Humidity Less than 80 RH Operating Pressure 500 mB 2 Bar Storage Temperature 40 C 60 C 40 F 140 F Power Consumption Approx 3 mA Battery Type 9V Battery Life 50 hours for 300mA hrs battery Dimension Meter 3 46 x 6 61 x ...

Страница 15: ...ng the On Off button 2 Remove the screw of the battery compartment cover and remove the battery compartment cover 3 Replace the old 9V battery with a new 9V battery 4 Replace the battery compartment cover and fasten the screw NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases ...

Отзывы: