background image

 

 

 

©  PCE Instruments 

 

Setting the time 

 
If  you  wish  to  change  the  time  displayed  on  the  device, 

press  the  button  when  “set  time”  is 

highlighted  inside the  “SET/MENU”  screen  (refer  to  picture  in  point  7 Menu  Instructions).  The 
highlighted  area  (beginning  with  the  year)  now  begins  to  count 

up

,  press  the  button  again  to 

confirm the desired value. After confirmation, the next value will be highlighted and begin to count

 

up

 (month). Repeat the process until you have the desired date and time set. 

 

10  Important notice 

 

Avoid direct sunlight; otherwise it can affect the measurement accuracy. 

 

The standard plate should be kept clean. Avoid touching it with your fingers. If there is 
dust  on  the  plate,  it can  affect the  measurement  accuracy.  Wipe  it with the  provided 
cloth or absolute alcohol. 

 

When the battery level is less than 20%, the batteries need to be replaced. Open the 
battery cover and replace the old batteries with new ones. Please note the polarity of 
the contact wires. 

 

The  batteries  should  be  replaced  when  depleted,  otherwise  long-term  storage  may 
cause  liquid to  leak  out  and  damage  the  device.  If  the  device  will  not  be  used  for  a 
longer period of time, the batteries should be taken out and kept in a safe place. 

 
 

11  Warranty 

You  can  read  our  warranty  terms  in  our  General  Business  Terms  which  you  can  find  here: 

https://www.pce-instruments.com/english/terms

 

12  Disposal 

For  the  disposal  of  batteries  in  the  EU,  the  2006/66/EC

 

directive  of  the  European  Parliament 

applies. Due to the contained pollutants, batteries must not be disposed of as household waste. 
They must be given to collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use 
them or give them to a recycling company which disposes of the devices in line with law. 
 
For  countries  outside  the EU,  batteries  and  devices  should  be  disposed  of  in accordance  with 
your local waste regulations. 
 
If you have any questions, please contact PCE Instruments. 
 

 

 

Содержание PCE-GM 75

Страница 1: ...s Meter User Manual User manuals in various languages français italiano español português nederlands türk polski русский 中文 can be found by using our product search on www pce instruments com Last change 2 December 2019 v1 0 English ...

Страница 2: ... Applications 2 3 Instrument Characteristics 2 4 Specifications 2 5 Display descriptions 2 6 Operation instructions 3 7 Menu instructions 3 8 Modifying the calibration value 3 9 Setting the time 4 10 Important notice 4 11 Warranty 4 12 Disposal 4 ...

Страница 3: ...ns The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case fo...

Страница 4: ...p High measurement precision Backlit LCD digital display with accurate battery life and time display Auditory feedback during operation Automatic shutdown USB interface for PC connection Stores up to 1245 measurements 4 Specifications Measuring range 0 99 9 GU 100 1000 GU Resolution 0 1 GU 1 GU Repeatability 0 45 GU 0 5 Accuracy 1 GU 1 Measurement geometry 60 Measuring surface Ø4 5 mm Data storage...

Страница 5: ...d 7 Menu instructions When the device is ready for use press and hold the button until the display changes and SET MENU is highlighted Release the button to enter the next screen The display change looks as follows The cursor now cycles top to bottom the options of the next menu Press the button when the desired option is highlighted in order to select 8 Modifying the calibration value If you wish...

Страница 6: ...ld batteries with new ones Please note the polarity of the contact wires The batteries should be replaced when depleted otherwise long term storage may cause liquid to leak out and damage the device If the device will not be used for a longer period of time the batteries should be taken out and kept in a safe place 11 Warranty You can read our warranty terms in our General Business Terms which you...

Страница 7: ...3 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands China Hong Kong PCE Brookhuis B V PCE Beijing Technology Co Limited PCE Instruments HK Ltd Institutenweg 15 1519 Room 6 Building Unit J 21...

Отзывы: