background image

 

 

©  PCE Instruments 

13 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 26 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 Soultz-Sous-Forets 

02500 Tobarra (Albacete) 

Deutschland 

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 

 

 

United Kingdom 

Italy 

Turkey 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

PCE Teknik Cihazları Ltd.Şti. 

Unit 11 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Halkalı Merkez Mah. 

Ensign Way, Southampton 

55010 Loc. Gragnano 

Pehlivan Sok. No.6/C 

Hampshire  

Capannori (Lucca) 

34303 Küçükçekmece - 

İstanbul 

United Kingdom, SO31 4RF 

Italia 

Türkiye 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Tel: 0212 471 11 47 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

www.pce-instruments.com/turkish 

 

 

 

The Netherlands 

United States of America 

PCE Brookhuis B.V. 

PCE Americas Inc. 

Institutenweg 15 

1201 Jupiter Park Drive, Suite 8 

7521 PH Enschede 

Jupiter / Palm Beach 

Nederland 

33458 FL 

Telefoon: +31 (0)53 737 01 92 

USA 

[email protected] 

Tel: +1 (561) 320-9162 

www.pce-instruments.com/dutch 

Fax: +1 (561) 320-9176 

 

   

[email protected] 

 

 

www.pce-instruments.com/us 

 

 

 

Содержание PCE-CT 2 BT Series

Страница 1: ...Coating Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Las...

Страница 2: ...off 4 7 Measurement 4 7 1 Continuous measurement 4 8 Menu 4 8 1 Menu structure 5 9 Calibration 5 9 1 Zero point calibration 6 9 2 One point calibration 6 9 3 Five point calibration 6 10 Data group 7...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...Fe Fe NFe Fe NFe Probe external internal external Measurement range 0 1500 m Resolution 0 1 m within meas range 0 99 9 m 1 m within meas range 100 1500 m Accuracy 1 m 2 of the coating thickness Units...

Страница 5: ...terial m Unit Adjustable units m and mil v Limit value Is displayed when the set limit value is exceeded or fallen below 17 Number of measurements Number of measured values 4 1 Key description Symbol...

Страница 6: ...nsor on the next measuring spot Important In order to obtain the best results it is important to take measurements on a smooth and non slip surface Do not impact the sensor head too forcefully on the...

Страница 7: ...mil Device information About Sensor type Type Serial number Serial Hardware version Hardware Software version Software 9 Calibration To perform a calibration the meter has various functions Factory ca...

Страница 8: ...asked whether you want to accept the calibration Press the key to save the change To discard the setting press the key 9 3 Five point calibration To perform a five point calibration first go to the ca...

Страница 9: ...e memory 11 Limit value alarm To set limit values first go to the limit alarm menu Under the item Alarm on you can activate the limit alarm function You can set the limits as follows Upper limit value...

Страница 10: ...You can find the driver in the program folder under the driver folder If you have a 64 bit system use the installation file CP210xVCPInstaller_x64 If you have a 32 bit system use the installation fil...

Страница 11: ...nection with a mobile device first download the Coatingmaster app Then switch on the Bluetooth function in the measuring device Now connect the coating thickness gauge via the app To do this select Co...

Страница 12: ...ngs to the app Setting Meaning Measuring sounds During a measurement a sound can be heard Measuring vibration When a measurement is made the vibration alarm is activated Alarm sounds When the limit is...

Страница 13: ...any measurements at the edge Incorrect placement of the probe Always align the probe vertically and quickly with the surface Do not perform a measurement by force The probe must touch the test object...

Страница 14: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Страница 15: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...

Отзывы: