background image

Model Number

670A01

ECHO® WIRELESS VIBRATION SENSOR

Revision: D

ECN #: 47051

Performance

ENGLISH

SI

RMS Velocity Frequency Range(± 3 dB)

4 to 2300 Hz

4 to 2300 Hz

[2]

Velocity HP Filter

2 Hz, 1-pole RC

2 Hz, 1-pole RC

Velocity LP Filter

2400 Hz,3-pole Chebyshev

2400 Hz,3-pole Chebyshev

Velocity Resolution

0.001 ips rms

0.025 mm/s rms

Velocity Range

4 ips rms

101.6 mm/s rms

RMS Acceleration Frequency Range(± 3 dB)

2.2 to 15 kHz

2.2 to 15 kHz

[2]

Acceleration HP Filter

2000 Hz,4-pole Chebyshev

2000 Hz,4-pole Chebyshev

Acceleration LP Filter

15k Hz, 3-pole Che 1-

pole RC

15k Hz, 3-pole Che 1-

pole RC

Acceleration Resolution

0.007 g pk

0.069 m/s² pk

[3]

Acceleration Range

20 g pk

196.2 m/s² pk

[3]

Transverse Sensitivity

 7 %

 7 %

Velocity Linearity(0-1 ips rms)

<1 %

<1 %

[4]

Velocity Linearity

(0-4 ips rms)

<8.5 %

<8.5 %

[4]

Acceleration Linearity

<1 %

<1 %

[4]

Environmental

Overload Limit(shock)

1000 g pk

9810 m/s² pk

Temperature Range

-4 to +158 °F

-20 to +70 °C

Enclosure Rating

IP66

IP66

Transmission Range

250 ft to>1 mile radius, 

installation dependent

250 ft to>1 mile radius, 

installation dependent

[1]

Electrical

RMS Velocity

Analog Integration, FFT Sum

Analog Integration, FFT Sum

RMS Acceleration

3.7 Sec time sample @ 61.4 

kHz sample rate

3.7 Sec time sample @ 61.4 

kHz sample rate

Filtered Crest Factor(max)

16

16

Frequency Band

900 MHz ISM Band

900 MHz ISM Band

Number of RF Bands

12

12

Maximum Power(ERP)

0.75 mW

0.75 mW

RF Data Rate

20 bps

20 bps

ADC/dynamic range

16 bit/>90db

16 bit/>90db

Battery Life(room temperature)

>5 years @ 3-measurements 

per day

>5 years @ 3-measurements 

per day

Electrical Isolation

>10

8

 Ohm

>10

8

 Ohm

Physical

Power

7.2V Lithium Battery Pack

7.2V Lithium Battery Pack

Size (Hex x Height)

1.375 in x 4.40 in

34.93 mm x 111.8 mm

Sensing Element

Ceramic

Ceramic

Weight

1 lb

454 g

Sensing Geometry

Shear

Shear

Housing Material

Stainless Steel

Stainless Steel

Housing Diameter

1.66 in

42.0 mm

Mounting

1/4" - 28

1/4" - 28

[5]

Mounting Torque

3 to 5 ft-lb

4 to 7 Nm

Sealing

O-Ring

O-Ring

Sensor Activation/Deactivation

Magnet Switch

Magnet Switch

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

is a registered trademark of PCB Group, Inc. 

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

CS

- Canadian Standards Association Approved Intrinsically Safe

[6]

M

- Metric Mount

Supplied Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1 (1)

NOTES:

[1] Typical.
[2] Upper frequency tolerance is ± 10% of the specified value.
[3] Conversion Factor 1g = 9.81 m/s².
[4] Zero-based, least-squares, straight line method.
[5] 1/4-28 has no equivalent in S.I. units.
[6] CL 1, Div 2, Groups A, B, C, D, T5

SUPPLIED ACCESSORIES: 

Model 081A40 Mounting Stud (1)

Entered: LK

Engineer: BAM

Sales: MC

Approved: BAM

Spec Number:

Date: 7/18/2017

Date: 7/18/2017

Date: 7/18/2017

Date: 7/18/2017

42657 

3425 Walden Avenue, Depew, NY 14043

Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]

Содержание IMISensors Echo 670A01

Страница 1: ...Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...41967 Rev E ECO 50473 Echo Wireless Vibration Sensor User s Manual...

Страница 7: ...screen similar to the following and then click on Echo EchoPlus Sensors 9 Factory Defaults 12 Explanation of Echo Wireless Sensor Parameters 12 Parameters can be changed by using the up and down arrow...

Страница 8: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicat...

Страница 9: ...esent Substitution of components may impair suitability for Class I Div 2 Avertissment Risque D explosion Ne pas debrancher ou brancher tant que le circuit est sous tension A moins qu il ne s agisse d...

Страница 10: ...erval is 8 hours 3 times per day An LED in the unit provides visual feedback on the state of the sensor off on but in sleep mode measuring transmitting and changing states The transmitted data is rece...

Страница 11: ...ompatible with the processes in your plant contact IMI for potential options Will Damage Polycarbonate Require Caution Considered Safe Alkali bleaches such as sodium hypochlorite Cyclohexanone Acetic...

Страница 12: ...longer take measurements The blue LED light allows the user to quickly determine the status of the unit by the time interval between blinks An active sensor will blink every 4 seconds while a deactiv...

Страница 13: ...ily available from computer electronics vendors Connect the Echo Programming Cable In general the Echo Programming Cable should be connected to the computer s serial port prior to connecting it to the...

Страница 14: ...ho Monitoring Software Launch the Echo Monitoring Software You should see a screen similar to the one below Click on Configuration on the menu bar You should see a screen similar to the following and...

Страница 15: ...cted click on Next The software will then prompt for what system components will be changed as shown below Note If you are setting up your actual database it is highly recommended that you configure t...

Страница 16: ...nnected to the computer then connect the micro USB connector to the sensor After the blue LED blinks 5 times click OK The following connection window will appear Select the appropriate COM port and cl...

Страница 17: ...actory set number for each sensor and cannot be changed Transmission Interval 8 hours RVL 0 off CF Report Threshold 0 02 Transmission Power High Transmission Band 1 Explanation of Echo Wireless Sensor...

Страница 18: ...divided by rms acceleration For a sine wave this value is 1 414 Echo sensors high pass filter both the true peak and rms acceleration measurements for better HFE high frequency energy response This ty...

Страница 19: ...er of the window Updating the Database to Match Sensor Programming If the sensor has not been previously entered into the database a message similar to the following will be displayed Click OK For det...

Страница 20: ...to the correct torque using a wrench on the hex base Outline Drawing See enclosed drawing Preparing the Surface If a clean flat spot is not available on the machine it is recommended to prepare a fla...

Страница 21: ...status The battery status is available for display in the Echo Monitoring Software See the Echo Monitoring Software User s Manual for details on monitoring the battery status The following are recomm...

Страница 22: ...s 1 Remove cap 2 Unplug and remove battery pack 3 Remove O ring and battery securing foam 4 Place the new O ring on the housing 5 Place grease completely around the O ring 6 Place grease on and around...

Страница 23: ...housing 9 Screw cap onto the housing a Make sure that the foam is centered on top of the batteries b Compress foam and hold so the threads of the cap and housing are touching c Turn the cap counter cl...

Страница 24: ...ange 16 bit 90db 16 bit 90db Battery Life room temperature 5 years 3 measurements per day 5 years 3 measurements per day Electrical Isolation 108 Ohm 108 Ohm Physical Power 7 2V Lithium Battery Pack 7...

Страница 25: ...005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 41966 1 OF 1 FULL M 670A SERIES WIRELESS DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JJF 2 26 20 JJF 2 26 20 YHK 2 26 20 41966 PCB Piezotronics Inc c...