PAGE 18
SENSO
RS AN
D INS
TRUME
N
TATIO
N F
OR MAC
HINE
CON
DITIO
N M
ONIT
ORIN
G
Parameter Options
There are several parameters that can be programmed to optimize performance of the Bearing Fault Detector
Plus. At any point during the programming process, the values can be changed between imperial and metric
measurements by clicking the Units dropdown in the top navigation menu and then selecting the appropriate
measurement type.
Machinery
Type
Output
Signal
Programmable
Parameter(s)
Range for Programmable
Parameter(s)
Constant Speed
Peak Acceleration
Full scale measurement range
2-50 g
19.61-490.33 m/s
2
RMS Acceleration
Full scale measurement range
2-50 g
19.61-490.33 m/s
2
Peak Acceleration
with Correction
Bearing diameter
1.57-19.98 in
40-500 mm
Rotation speed
600-4,800 RPM
Variable Speed
Crest Factor
N/A
N/A
Crest Factor Plus
N/A
N/A
Unless otherwise specified, the sensor comes from the factory with a default setting of peak acceleration output
with a full scale of 8g peak.