background image

 

 

MS 

 Mine Safety Approved Sensors 

TO 

 Temperature Output Sensor 

 

Note

Not all sensors are available with the optional 

prefixes.  Contact  the  factory  to  discuss  special 
features that may be needed.

 

 
4.0 INSTALLATION OVERVIEW

 

When choosing a mounting method, consider closely both 
the  advantages  and  disadvantages  of  each  technique. 
Characteristics like location, ruggedness, amplitude range, 
accessibility,  temperature,  and  portability  are  extremely 
critical.  However,  the  most  important  and  often 
overlooked  consideration  is  the  effect  the  mounting 
technique  has  on  the  high-frequency  operating  range  of 
the accelerometer.  
 
Shown  in  Figure  4  are  six  possible  mounting  techniques 
and  their  effects  on  the  performance  of  a  typical 
piezoelectric  accelerometer.  (

Note: 

Not  all  of  the 

mounting methods may apply to your particular sensor.

The  mounting  configurations  and  corresponding  graph 
demonstrate  how  the  high-frequency  response  of  the 
accelerometer may be compromised as mass is added to 
the system and/or the mounting stiffness is reduced.

 

 
Note:

  The  low-frequency  response  is  unaffected  by  the 

mounting technique. This roll-off behavior is typically fixed 
by 

the  sensor’s  built

-in  electronics.  However,  when 

operating  AC-coupled  signal  conditioners  with  readout 
devices  having  an  input  impedance  of  less  than  one 
megaohm, the low frequency range may be affected. 

 

 
 
 

4.1 STANDARD STUD MOUNT

 

This  mounting  technique  requires  smooth,  flat 
contact  surfaces  for  proper  operation  and  is 
recommended  for  permanent  and/or  secure 
installations.  Stud  mounting  is  also  recommended 
when testing at high frequencies. 

 
Note: 

Do  NOT  attempt  mounting  on  curved,  rough, 

or uneven surfaces, as the potential for misalignment 
and limited contact surface may significantly reduce 

the  sensor’s  upper  operating  frequency  range. 

 

 
STEP  1: 

First,  prepare  a  smooth,  flat  mounting 

surface and then drill and tap a mounting hole in the 
center of this area as shown in Figure 5.  
 
A  precision-machined  mounting  surface  with  a 
minimum  finish  of  63  µin  (0.0016  mm)  is 
recommended. (If it is not possible to properly prepare 
the  machine  surface,  consider  using  an  adhesive 
mounting  pad  as  a  possible  alternative.)  Inspect  the 
area, checking that there are no burrs or other foreign 
particles interfering with the contact surface. 

 
STEP 2: 

Wipe clean the mounting surface and spread 

on a light film of grease, oil, or similar coupling fluid 
prior to installation.  See Figure 6. 

 

Adding  a  coupling  fluid  improves  vibration 
transmissibility by filling small voids in the mounting 
surface  and  increasing  the  mounting  stiffness.  For 

Содержание IMI SENSORS EX637 Series

Страница 1: ...el 25mV g 4 to 1 5kHz side exit 2 pin conn Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLin...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...lated 2 20 mA at 18 to 28 VDC source This power is regulated by a current limiting circuit which provides the constant current excitation required for proper operation of ICP sensors In general batter...

Страница 7: ...sential as the reliability and accuracy of any measurement system is no better than that of its weakest link Due to the nature of vibration measurements all sensor cables will ultimately fatigue and f...

Страница 8: ...CB Piezotronics This Division is wholly contained in the PCB Piezotronics manufacturing facility at 3425 Walden Avenue Depew New York Same address same manufacturing facility Some of the documentation...

Страница 9: ...ON A ECN NUMBER 49766 Operating Guide with Enclosed Warranty Information 3424 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI Piezoelectric IC...

Страница 10: ...ply low frequency and high frequency measurements Shear design sensors are preferred because of their inherent insensitivity to adverse environmental influences such as case or base strain and thermal...

Страница 11: ...wer gain which is extremely close to unity and independent of input voltage Also the diode can be changed to supply higher currents for driving long cable lengths Constant current diodes as shown in F...

Страница 12: ...nics However when operating AC coupled signal conditioners with readout devices having an input impedance of less than one megaohm thelow frequencyrangemaybeaffected 4 1 STANDARD STUD MOUNT This mount...

Страница 13: ...derside of the mounting base Firmly press down on the assembly to displace any extra adhesive remaining under the base See Figure7 METHOD 2 Direct Adhesive Mount For restrictions of space or for conve...

Страница 14: ...interference or radio frequency interference EMI or RFI To avoid ground loops thereshouldonlybeonegroundin the system It is recommended for permanent installations that the sensor becase isolatedand...

Страница 15: ...ate Also any current not used by the cable goes directly to power the internal electronicsandwillcreateheat Thismaycausethesensorto exceed its maximum temperature specification For this reason donotsu...

Страница 16: ...er the meter or LED and allow the sensor to power up If a faulty condition is monitored first check all system connections then check the functionality of the cable and signal conditioner If the syste...

Страница 17: ...and former MIL STD 45662A and uses equipment directly traceable to NIST This assures an accurate calibration of relevant specifications The following includes a broad overview of the Back to Back Cal...

Страница 18: ...A of constant current to extend battery life while continuous monitoring systems offer more current in order to drive longer cables Figure 16 shows a typical system for a sensor with integral electron...

Страница 19: ...eive assistance via e mail at imi pcb com or visit our website at www pcb com 11 0 CUSTOMER SERVICE WARRANTY IMI a division of PCB Piezotronics guarantees Total Customer Satisfaction If at any time fo...

Страница 20: ......

Страница 21: ...O DRAFTING 49059 NO CHANGES WITHOUT APPROVAL SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE NOTIFIED BODY SHIELDS TO BE EARTHED AT BARRIER ENDS THE INSTALLER SHALL INSURE THAT TH...

Страница 22: ...n Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN SEE SHEET 1 SCHEDULE DRAWING NO MODIFICATIONS PE...

Страница 23: ...UNF 5 MountingTorque 2 to5 ft lb 2 7 to6 8 Nm SensingElement Quartz Quartz SensingGeometry Shear Shear HousingMaterial Stainless Steel Stainless Steel Sealing Hermetic Hermetic 6 Electrical Connector...

Страница 24: ...CASE ISOLATED ACCELEROMETER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KRM 12 13 18 KRM 12 13 18 RMB 12 13 18 68326 PCB Piezotronics Inc claims proprietary rights in the information disclosed here...

Страница 25: ...tes that the product is subject to the special conditions of use specified in the Schedule to this certificate 9 This EU Type Examination Certificate relates only to the design and construction of the...

Страница 26: ...The relevant Essential Health and Safety Requirements EHSR5 have been identified and assessed in lntertek Report 103312845CRT 003a Dated 8 August 2019 This Certificate is forth exclusive use of Intert...

Страница 27: ...9 MODEL EX M 637XYYYZ SERIES ETCHING DRAWING Page 1 o 2 This Certificate Is for the exclusive use of Intertek s client and is provided pursuant to the agreement between Intertek and its Client Interte...

Страница 28: ...f Intertek s client and is provided pursuant to the agreement between Intertek and its Client lntertek n responsibility and liability are limited to the terms and conditions of the agreement Intertek...

Страница 29: ...number it indicates that the product is subject to the special conditions of use specified in the Schedule to this certificate 9 This Type Examination Certificate relates only to the design of the spe...

Страница 30: ...C 60079 15 Unused connector must be fitted with an appropriately rated blanking cover b Conditions of Manufacture Routine Tests Dielectric Strength Test Per IEC 60079 15 14 Essential Health and Safety...

Страница 31: ...3 ETCHING DRAWING 70897 NR 8 8 19 MODEL EX M 637XYYYZ SERIES ETCHING DRAWING Page lof 2 This Certificate is for the exclusive use of lutertek s client and is provided pursuant to the agreement between...

Страница 32: ...of lntertek s client and is provided pursuant to the agreement between Intertek and its Client ietertek s responsibility and liability are limited to the terms and conditions of the agreement Intertek...

Страница 33: ...Number This Authorization to Mark is for the exclusive use of Intertek s Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek s responsibility and li...

Страница 34: ...nd Non Incendive Equipment For Use In Hazardous Locations R2016 CSA C22 2 157 1992 Ed 3 GI U2 Nonincendive Electrical Equipment For Use In Class I And II Division 2 And Class III Divisions I And 2 Haz...

Страница 35: ...YYYZ EX M 638XYYYZ Optional accessory Type of Protection IntrinsicSafety Ia Non Sparking nA Marking Ex ia IIC T4 Ga Ex nA IIC T4 Gc 1960 5 Ta 5 121 C lECEx ETL 19 0034X Approved for issue on behalf of...

Страница 36: ...erational Documents as amended STANDARDS The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents was found to comply with the follo...

Страница 37: ...barrier item When used in Zone 2 The Accelerometers provide a voltage output when subjected to mechanical motion They are intended to be fixed installation in the explosive atmosphere and to be suppl...

Страница 38: ...98 NR 7 24 2019 SECURITE INTRINSEQUE NON SPARK ARC lECEx Ex Ia lECEx Ex nA EX M 637XYYYZ Series Industrial ICP Accelerometer EX M 638XYYYZ Series Industrial ICP Accelerometer Page 2 of 2 DESCRIPTIVE N...

Страница 39: ...ETCHING DRAWING Page 1 of 2 ETCHING DRAWING 70900 NR 8 8 19 MODEL EX M 638XYYYZ SERIES ETCHING DRAWING Page 2 of 2 APPROVAL 70910 NR 7 27 19 INTERCONNECTION DIV 1 ZONE 0 Page 1 of APPROVAL 70910 NR 7...

Страница 40: ...INSTRUCTIONS FOR USE 70911 NR 08 01 19 EX M 637XYYYZ and EX M 638XYYYZ Series Page 3 of 3 APPROVAL XTAL 71165 NR 7 24 19 DRAWING Page 1 of 1 Note An is included before the title of documents that are...

Страница 41: ...data sheets and where those data sheets refer to this declaration of conformity The data sheets for all ICP model numbers referenced above which include the CE mark on such data sheets and refer to th...

Страница 42: ...045c GM29047c GM29029s GM29031s GM29033s GM29044s GM29046s GM29048s I the undersigned hereby declare that the equipment specified above conforms to the above Directive s Standard s Place Depew NY Date...

Страница 43: ...erenced above which include the CE mark on such data sheets and refer to this Declaration of Conformity are hereby incorporated by reference into this Declaration Conform to the following UK Legislati...

Страница 44: ...045c GM29047c GM29029s GM29031s GM29033s GM29044s GM29046s GM29048s I the undersigned hereby declare that the equipment specified above conforms to the above Directive s Standard s Place Depew NY Date...

Отзывы: