Specifications: 

Frequency Range: 2.6MHz~65MHz 
RF Output Level: 2Vp-p 
SWR Range: 1~10(Freq<30MHz), 1~6(Freq >=30MHz) 
Impedance Range: 10-200ohm 
Battery: 8 * AA Alkaline Battery 
Power Consumption: <= 160mA 
 

External Connectors: 

• 

9.6-12V DC Power Supply 

• 

PL-259 Antenna Socket 

 

Buttons: 

• 

Power Button (PWR) 

• 

Frequency Up Button (UP) 

• 

Frequency Down Button (DOWN) 

• 

Selection Function Button (SELECT) 

• 

Quick Button (QUICK) 

Power On: 

1.  Tap  the  PWR  button.  The  first  screen  shows  the  modal  number  AW06A  and  the  designer’s 

amateur radio call sign.  

2.  Press  SELECT  button  to  continue  the  operation  with  the  LCD  backlight,  press  any  other 

buttons will turn off the LCD backlight.  

Field Test: 

1.  Press QUICK button to start a field radio strength test. 
2.  The antenna analyzer will turn off the local PLL and measure the radio signal strength on the 

RF  socket.  A  fake  SWR  will  be  shown  on  the  LCD,  ideally  the  value  is  1  which  means  no 
significant  interference  is  detected  from  the  RF  socket.  Practically,  the  interference  is 
acceptable if the fake SWR is less than 2. 

3.  Press SELECT button to go back to the power on idle screen. 

SWR Measurement: 

1.  Press SELECT button from idle screen to start SWR measurement. 
2.  Press  UP  and  DOWN  button  to  set  the  start  frequency,  which  is  the  lowest  frequency  of 

automatic scanning range. Push the SCAN button at the same time with UP or DOWN button 